Análisis técnico y económico del alumbrado público vial de la ciudad de Cuenca, comparando luminarias led vs las de descarga, en función de la polución lumínica que producen

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/31645
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCampoverde Armijos, Freddy Fernando-
dc.contributor.authorGodoy Armijos, Danny Pablo-
dc.contributor.authorGualan Andrade, Miguel Gabriel-
dc.date.accessioned2025-10-28T21:08:55Z-
dc.date.available2025-10-28T21:08:55Z-
dc.date.issued2025-02-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/31645-
dc.descriptionCon la siguiente investigación se pudo analizar el impacto del alumbrado público vial en la ciudad de Cuenca, enfocándose en los efectos negativos de la iluminación artificial, como es la contaminación lumínica. A pesar de los avances tecnológicos se pudo demostrar, que muchas luminarias aún generan dispersión excesiva de luz, afectando así al medio ambiente como la visión de las personas. Con el estudio se compara luminarias LED y luminarias de descarga, evaluando sus implicaciones económicas y ambientales. Para ello, se aplicó métodos de medición como el de 9 puntos y de malla, con instrumentos específicos que permiten cuantificar la contaminación lumínica. Para concluir se, analizo parámetros eléctricos y lumínicos para determinar cuál de las dos tecnologías es más viable para implementar en el alumbrado público, conforme a normativas locales e internacionales de acuerdo con ARCERNNR-007/23.spa
dc.description.abstractThe following research analyzed the impact of street lighting in the city of Cuenca, focusing on the negative effects of artificial lighting, such as light pollution. Despite technological advances, it was demonstrated that many luminaires still generate excessive light dispersion, thus affecting the environment and people's vision. The study compares LED and discharge luminaires, evaluating their economic and environmental implications. To this end, measurement methods such as the 9-point and mesh methods were applied, using specific instruments that allow quantifying light pollution. Finally, electrical and lighting parameters were analyzed to determine which of the two technologies is more viable for implementation in public lighting, in accordance with local and international regulations in accordance with ARCERNNR-007/23.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectALUMBRADO PÚBLICO - ASPECTOS AMBIENTALESspa
dc.subjectLÁMPARAS ELÉCTRICASspa
dc.subjectLÁMPARAS LEDspa
dc.subjectLUMINISCENCIAspa
dc.subjectCUENCA (AZUAY, ECUADOR) - ALUMBRADOspa
dc.titleAnálisis técnico y económico del alumbrado público vial de la ciudad de Cuenca, comparando luminarias led vs las de descarga, en función de la polución lumínica que producenspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Cuencaspa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-CT012331.pdfTexto completo7,56 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons