Abstract: El Gobierno de la República del Ecuador para disminuir la demanda de energía eléctrica de los usuarios residenciales, impulsó el plan de cambio de focos incandescentes por ahorradores en varios sectores del país, siendo beneficiosos para los usuarios, las empresas eléctricas y el país en general por la disminución del consumo, pero se hace indispensable realizar un estudio técnico experimental de los efectos adversos a la calidad de energía eléctrica que se producen por el uso de focos ahorradores en las residencias, por medio del cual se deje en evidencia las desventajas que estos presentan, como el incremento de armónicos que se introducen a las redes eléctricas, el bajo factor de potencia, el aumento en las distorsiones de voltaje y la calidad en los niveles de iluminación. Este documento se basa en las mediciones, análisis de resultados y verificación del cumplimiento de las normas de los factores que afectan a la calidad de la energía eléctrica y perjudican directamente a las Empresa Eléctricas y a los usuarios residenciales, además se realizó una comparación de la cantidad de iluminación de los focos ahorradores comparadas con la de los focos incandescentes.
Description: The Government of the Republic of Ecuador to reduce electricity demand for residential users, pushed the plan change incandescent light bulbs with energy saving in various sectors of the country, being beneficial for users, utilities and the country in general the decline in consumption, but it is essential to conduct a pilot technical study of adverse effects on the quality of power produced by the use of energy saving light bulbs in homes, whereby evidence is left disadvantages they present as increasing harmonics are introduced to electricity networks, low power factor, the increase in voltage distortion and quality in lighting levels. This document is based on measurements, analysis of results and verification of compliance with the rules of the factors affecting the quality of electricity and directly harm the Power Company and residential users, plus a comparison of the amount was made lighting saving bulbs compared to incandescent bulbs. It was determined that% energy-saving bulbs is within the range of quality established by the existing normalization and recommended in this document and that outbreaks do not meet these values.
URI: http://dspace.ups.edu.ec/handle/123456789/1875
Appears in Collections:Ingeniería Eléctrica SUR - Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
00 Indice.pdfINDICE64.72 kBAdobe PDFView/Open
01 Introduccion Objetivos Alcance.pdfCAPITULO I63.02 kBAdobe PDFView/Open
02 Funcionamiento focos ahorradores.pdfCAPITULO II405.98 kBAdobe PDFView/Open
03 Analisis de armonicos y fp.pdfCAPITULO III192.99 kBAdobe PDFView/Open
04 Analisis experimental de funcionamientos.pdfCAPITULO IV510.62 kBAdobe PDFView/Open
99 Conclusiones y Recomendaciones.pdfCONCLUSIONES Y RECOMENDACIONES74.85 kBAdobe PDFView/Open