Determinación de tratamientos primarios para la depuración del agua residual doméstica

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/13065
Título : Determinación de tratamientos primarios para la depuración del agua residual doméstica
Autor : Paladines Quichimbo, Alex Manuel
Salazar Cárdenas, Andrea Jazmín
Director de Tesis: Borja Vela, Ximena del Rocío
Resumen traducido: El tratamiento de aguas residuales se ha venido estudiando desde hace mucho tiempo, por lo tanto, es común ver que se aplique las mismas operaciones y procesos unitarios adaptados a las condiciones de diferentes sitios. Para el presente estudio se pretendió determinar las unidades de tratamiento primario más adecuadas, para la depuración de aguas residuales domésticas, basándose en la calidad del agua residual del sector de Guapulo de Quito D.M. Con la finalidad de indagar que unidades son convenientes aplicar en el proceso previo al ingreso de un reactor de lodos activados se analizó la calidad del ARD, se diseñó y se construyó las unidades más apropiadas para depurar el agua de estudio, y una vez determinadas se planteó dos modelos de tratamiento primario con el fin de obtener cuál de ellos es el más efectivo. El modelo seleccionado se resume en: cribado, tanque de homogenización, desarenador aireado de flujo helicoidal con una concentración de oxigeno baja (M1C1); el cual fue operado en las instalaciones del laboratorio de hidráulica de la Universidad Politécnica Salesiana. Los parámetros turbidez, sólidos totales, aceites y grasas; tenían valores de 122,85 NTU; 581,75 mg/L; 987,2 mg/ respectivamente, antes de ingresar al modelo y luego del tratamiento, se obtuvo valores de 75,3 NTU para turbidez; 62,2 mg/L en sólidos totales y 81,1 mg/L en A/G; por ende, los porcentajes de remoción son los siguientes: para turbidez tenemos 75,3%, sólidos totales 62,2% y A/G 81,1%.
Resumen : The wastewater treatment has been studied for a long time; therefore, it is common to apply the same operations and unit processes adapted to the conditions of different sites. For the present study was intended to determine the most appropriate primary treatment units for the purification of domestic wastewater, based on the quality of wastewater from Quito Guapulo sector. In order to ascertain which units are suitable for application prior to a reactor-activated sludge it was necessary to analyzed the quality of domestic wastewater, also it has been designed and built the most appropriate purification units based on the wastewater sample. Once the primary treatment was determined, it was posed two models in order to obtain which of them is the most effective. The selected system is summarized in screening, homogenization tank, helical flow aerated sand trap with a low oxygen concentration (M1C1); which it was operated in the hydraulic laboratory facilities of Universidad Politécnica Salesiana. The turbidity parameters, total solids, oil and greases; values were 122,85 NTU; 581,75 mg / L; 987,2 mg / respectively, before entering the model and after passing through the select model the values obtained were turbidity 75,3 NTU; 62,2 mg / L total solids and 81,1 mg / L in oil and greases; therefore, removal percentages are: 75,3% for turbidity, 62,2% total solids and oil and greases 81,1%.
Palabras clave : AGUA - PURIFICACIÓN
AGUAS RESIDUALES
Fecha de publicación : jun-2016
URI : https://dspace.ups.edu.ec/handle/123456789/13065