dc.descriptionEl presente estudio aborda el modelado y simulación de la anatomía de la cadera en un paciente pediátrico con luxación congénita bilateral, se describe el diseño del estudio, iniciando por datos relevantes como los datos del paciente elegido, es una lactante menor de sexo femenino y se realizaron exámenes físicos y ecográficos que evidenciaron la luxabilidad de la cadera. Cabe recalcar la importancia del diagnóstico precoz, mediante exámenes clínicos exhaustivos y estudios ecográficos, considerando datos geométrico morfométrico de la anatomía de la cadera, mediciones de los ángulos alfa y beta, y la distancia de cobertura ósea y el diámetro máximo de la cabeza femoral. La luxación congénita o displasia del desarrollo de la cadera consiste en una afección osteomuscular presentada frecuente en niños menores de 2 años, la solución a largo plazo para que los infantes logren tener una adecuada funcionalidad de la articulación en la edad adulta es un diagnóstico temprano. Según los argumentos presentados, es necesario simular y analizar el comportamiento biomecánico de la cadera de un lactante con luxación congénita bilateral usando elementos finitos, estos análisis permiten modelar y simular la articulación de la cadera, considerando las propiedades mecánicas y las fuerzas aplicadas, esto da información detallada sobre tensiones y deformaciones al personal médico a cargo del caso. Permite tener una mejor comprensión de los mecanismos de la enfermedad y a planificar tratamientos, siendo también útil en el diseño y optimización de dispositivos ortopédicos y toma de decisiones para mejorar la función y calidad de vida de los pacientes con luxación congénita de cadera.spa
dc.description.abstractThe present study deals with the modeling and simulation of the hip anatomy in a pediatric patient with bilateral congenital dislocation. The design of the study is described, starting with relevant data such as the patient's data, a female infant and physical and ultrasound examinations that showed the dislocation of the hip. It is important to emphasize the importance of early diagnosis, by means of exhaustive clinical examinations and ultrasound studies, considering geometric morphometric analysis data of the hip anatomy, measurements of the alpha and beta angles, as well as the bone coverage distance and the maximum diameter of the femoral head. Congenital dislocation or developmental dysplasia of the hip is an osteomuscular condition frequently presented in children under 2 years of age, the long-term solution for infants to achieve an adequate functionality of the joint in adulthood is an early diagnosis. Based on the arguments presented, it is necessary to perform the simulation and analysis of the biomechanical behavior of the hip of an infant with bilateral congenital dislocation using the finite element technique, these analyses allow modeling and simulating the hip joint, considering the mechanical properties and applied forces, this provides detailed information on stresses and deformations to the medical staff in charge of the case. It allows to have a better understanding of the disease mechanisms and to plan treatments, being also useful in the design and optimization of orthopedic devices and decision making to improve the function and quality of life of patients with congenital hip dislocation.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectBIOMEDICINAspa
dc.subjectINTELIGENCIA ARTIFICIALspa
dc.subjectBIOMECÁNICAspa
dc.subjectLUXACIÓN CONGÉNITAspa
dc.subjectECOGRAFÍAspa
dc.titleSimulación y análisis del comportamiento biomecánico de la cadera de un lactante menor con luxación congénita bilateral mediante elementos finitosspa