Parametrización y puesta en servicio de un Intellirupter instalado en la red de medio voltaje de un alimentador primario de distribución

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/26170
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRojas Espinoza, Jorge Luis-
dc.contributor.authorQuito Vidal, Bryan Gerardo-
dc.contributor.authorReyes Reinoso, Daniela Alejandra-
dc.date.accessioned2023-10-06T13:15:45Z-
dc.date.available2023-10-06T13:15:45Z-
dc.date.issued2023-10-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/26170-
dc.descriptionEn el presente artículo se explica la puesta en servicio de un Intellirupter de S&C Electric Company en la red de medio voltaje de un alimentador primario de distribución perteneciente a la Empresa Eléctrica Azogues, de la ciudad de Azogues - Ecuador. Se ha tomado como caso de estudio el alimentador 124 ubicado en la zona céntrica de la ciudad, que opera a 22kV con una demanda máxima de 2.04MVA. La puesta en servicio del equipo se realizó previa coordinación de protecciones con base en los parámetros de falla, la parametrización de las diferentes señales analógicas y digitales que se desea controlar, y la integración al sistema SCADA de la Empresa Eléctrica. Con la puesta en marcha del equipo se espera disminuir los tiempos de interrupción del suministro eléctrico y mejorar los índices de confiabilidad, resultados que se verán reflejados a largo plazo por medio de un análisis comparativo con el histórico de los índices FMIK y TTIK.spa
dc.description.abstractIn this article, the commissioning of an Intellirupter by S&C Electric Company in the medium voltage network of a primary distribution feeder belonging to the Electric Company Azogues, is explained. The feeder 124, operating at 22kV with a maximum demand of 2.04MVA, has been taken as a case study. The commissioning of the equipment was carried out after coordinating protections based on fault parameters, parameterizing the different analog and digital signals to be controlled, and integrating it into the SCADA system of the Electric Company. By implementing this equipment, it is expected to reduce power supply interruption times and improve reliability indices. These results will be reflected in the long term through a comparative analysis with historical FMIK and TTIK indices.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICA - PROTECCIÓNspa
dc.subjectSUMINISTRO ININTERRUMPIDO DE ENERGÍAspa
dc.subjectLOCALIZACIÓN DE FALLAS ELÉCTRICASspa
dc.titleParametrización y puesta en servicio de un Intellirupter instalado en la red de medio voltaje de un alimentador primario de distribuciónspa