Reducción de armónicos creados por corrientes no sinusoidales debido a la presencia de cargas no lineales, mediante transformadores con conexión en zigzag en el sistema de distribución residencial

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/24833
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrizondo Martínez, Rogelio Alfredo-
dc.contributor.authorRosero Sangucho, Myke Richard-
dc.date.accessioned2023-05-11T14:30:38Z-
dc.date.available2023-05-11T14:30:38Z-
dc.date.issued2023-04-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/24833-
dc.descriptionLa evolución tecnológica en los equipos electrónicos ha crecido considerablemente en el sector residencial, por lo que su inclusión crecerá con el pasar de los años. El consumo no lineal de los componentes con los cuáles son diseñados, repercuten negativamente dentro del sistema de distribución, ocasionando daños en equipos, especialmente en el transformador que alimenta a dichas cargas, reduciendo su vida útil, además de una deficiente calidad de suministro eléctrico. Con estos antecedentes, el objetivo puntual de la presente investigación se enfoca en reducir los armónicos originados por este tipo de cargas. Para lograrlo, el método aplicado será a través de la conexión en zigzag, el cual se lo realiza en el sistema de 13 barras IEEE, comparando las conexiones entre los devanados del transformador en Yy y Yz, por medio de la simulación en DigSILENT. Mediante esto se podrá realizar un análisis basado en la obtención del espectro armónico HDi y THDi, así como a través de la tabulación de datos. De esta manera, se encontrará la conexión más eficaz para reducir el tercer armónico, y por ende sus componentes de secuencia cero.spa
dc.description.abstractThe technological evolution in electronic equipment has grown considerably in the residential sector, so it’s inclusion will grow over the years. The non-linear consumption of the components with which they are designed, have a negative impact on the distribution system, causing damage to equipment, especially in the transformer that feeds these loads, reducing their useful life, in addition to a poor quality of power supply. With this background, the specific objective of this research is focused on reducing the harmonics originated by this type of loads. To achieve this, the method applied will be through the zigzag connection, which is performed in the IEEE 13-bus system, comparing the connections between the windings of the transformer in Yy and Yz, by means of simulation in DigSILENT. Through this, an analysis based on obtaining the harmonic spectrum HDi and THDi, as well as through data tabulation, can be performed. In this way, the most effective connection to reduce the third harmonic, and therefore it’s zero sequence components, will be found.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectREDUCCIÓN DE ARMÓNICOSspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.subjectCARGAS NO LINEALESspa
dc.subjectCONEXIONES ELÉCTRICASspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.titleReducción de armónicos creados por corrientes no sinusoidales debido a la presencia de cargas no lineales, mediante transformadores con conexión en zigzag en el sistema de distribución residencialspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa