Control de un variador de frecuencia altivar 320 con PLC MODICON M241 a través de comunicación MODBUS RTU para el laboratorio de automatización industrial

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/20671
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorLima Cedillo, Byron Xavier-
dc.contributor.authorParra Pibaque, Aurelio Antony-
dc.contributor.authorMiranda Feijoó, Gabriel Fabricio-
dc.date.accessioned2021-08-05T16:03:59Z-
dc.date.available2021-08-05T16:03:59Z-
dc.date.issued2021-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/20671-
dc.descriptionEl presente proyecto técnico de titulación: “Control de un variador de frecuencia Altivar 320 con PLC Modicon M241 a través de comunicación modbus RTU”, se basa en el control de un motor trifásico de la marca Siemens, mediante un variador de frecuencia Altivar 320 de la marca Schneider Electric, a través del protocolo de comunicación Modbus RTU RS485 entre el variador de frecuencia y el PLC Modicon TM241CE24R. El propósito principal de este proyecto es diseñar e implementar una maleta didáctica y dar a conocer a los estudiantes el protocolo de comunicación Modbus RTU RS485. Para un mejor entorno de aprendizaje en el desarrollo de esta maleta didáctica, se utilizan: un motor trifásico síncrono, de la marca Siemens; un Variador de Frecuencia Altivar Machine ATV320U07M2C, un PLC Modicon TM241CE24R, un Magelis GTO Panel HMIGTO2310. Estos tres últimos equipos mencionados de la marca Schneider Electric. Con esta maleta didáctica, los estudiantes de la Universidad Politécnica Salesiana, podrán simular sistemas y procesos industriales entre los cuales tenemos: sistemas de presión constate, arranque de motores, control de nivel, etc.spa
dc.description.abstractThe present technical degree project: "Control of an Altivar 320 frequency inverter with Modicon M241 PLC through Modbus RTU communication", is based on the control of a Siemens brand three-phase motor, employing a Schneider Electric’s Altivar 320 frequency inverter, through the Modbus RTU RS485 communication protocol between the frequency inverter and the Modicon TM241CE24R PLC. The main purpose of this project is to design and implement a didactic case and to introduce students to the Modbus RTU RS485 communication protocol. For better learning, the case is composed of an asynchronous three-phase motor, from the Siemens brand; an Altivar Machine ATV320U07M2C Variable Frequency Drive, a Modicon TM241CE24R PLC, a Magelis GTO Panel HMIGTO2310. These last three pieces of equipment are from Schneider Electric. With this didactic case, the students of the Salesian Polytechnic University are going to be able to simulate industrial systems and processes, among which we have: constant pressure systems, motor start-ups, level control, etc.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectAUTOMATIZACIÓN INDUSTRIALspa
dc.subjectARRANQUE DE MOTORESspa
dc.subjectMALETA DIDÁCTICAspa
dc.subjectPRESIÓN CONSTATEspa
dc.subjectCONTROL DE NIVELspa
dc.subjectPROCESOS INDUSTRIALESspa
dc.titleControl de un variador de frecuencia altivar 320 con PLC MODICON M241 a través de comunicación MODBUS RTU para el laboratorio de automatización industrialspa
dc.typebachelorThesisspa
ups.carreraIngeniería Electrónicaspa
ups.sedeSede Guayaquilspa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-GT003316.pdfTexto completo9,73 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons