Análisis del sistema eléctrico en baja tensión (BT) de la Universidad Politécnica Salesiana Campus Sur usando la captura de datos en campo para mejorar la eficiencia energética

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19249
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRuiz Maldonado, Milton Gonzalo-
dc.contributor.authorCollaguazo Chipantasi, Pedro Javier-
dc.date.accessioned2020-09-23T00:55:48Z-
dc.date.available2020-09-23T00:55:48Z-
dc.date.issued2020-09-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/19249-
dc.descriptionEl presente proyecto técnico presenta el análisis del sistema eléctrico de la Universidad Politécnica Salesiana campus sur bloque “G” y auditorios, mediante el cual se comprobó el funcionamiento del sistema eléctrico, la seguridad de los equipos y personal destinado a maniobrar o dar mantenimiento los dispositivos. Para la obtención de datos en campo se procedió a utilizar equipos como lo son el analizador trifásico, secuencímetro, telurómetro, cámara termográfica con la finalidad de obtener datos como voltaje, corriente, potencia, temperatura, resistividad entre otros, los cuales permitieron realizar un estudio del estado actual del sistema eléctrico y verificar si cumple la norma NEC-2017 como estado físico, ambiente al cual son sometidos los equipos, señalización, ampacidad. El análisis térmico se realizó con el fin de encontrar puntos calientes en el sistema o equipos que estén sobre su temperatura de diseño, que afectan de manera negativa y no permita una buena calidad de energía. Con un plan de mejora se plantea un diseño de malla de puesta a tierra acorde a la normativa IEEE 80-2013, se procedió a realizar un diseño que permita mejorar la eficiencia del sistema eléctrico de la universidad con energía de calidad acorde a la regulación 004/01 del CONELEC.spa
dc.description.abstractThis technical project presents the analysis of the electrical system of the Salesian Polytechnic University campus sur block "G" and auditoriums, through which the operation of the electrical system was checked, the safety of equipment and personnel intended to maneuver or maintain the devices. For the obtaining of data in the field, equipment such as the three-phase analyzer, sequenmeter, telurometer, thermal imaging camera was used in order to obtain data such as voltage, current, power, temperature, resistivity among others, which allowed to carry out a study of the current state of the electrical system and check if it complies with the NEC-2017 standard as a physical condition, environment to which the equipment is subjected, signage, amppacity. The thermal analysis was performed in order to find hot spots in the system or equipment that are above its design temperature, which negatively affect and does not allow a good energy quality. With an improvement plan, a grounding mesh design is proposed according to IEEE 80-2013, a design was carried out to improve the efficiency of the university's electrical system with quality energy according to CONELEC regulation 004/01.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectCONEXIONES MONOFASICASspa
dc.subjectUNIVERSIDADESspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.titleAnálisis del sistema eléctrico en baja tensión (BT) de la Universidad Politécnica Salesiana Campus Sur usando la captura de datos en campo para mejorar la eficiencia energéticaspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS151.pdfTexto completo7,88 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons