REMOCIÓN DE CONTAMINANTES ORGÁNICOS PRESENTES EN AGUA RESIDUAL DOMÉSTICA MEDIANTE PROTOTIPO A ESCALA DE LABORATORIO

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/14793
Título : REMOCIÓN DE CONTAMINANTES ORGÁNICOS PRESENTES EN AGUA RESIDUAL DOMÉSTICA MEDIANTE PROTOTIPO A ESCALA DE LABORATORIO
Autor : Mejía-López, Ana
Cabrera, Mario
Carrillo, Yurina
Resumen traducido: En la comúnidad de Púlingúí perteneciente a la parroqúia de San Andrés del cantón Gúano provincia de Chimborazo, Ecúador se tratan las agúas residúales domésticas en ún sistema de tanqúes sépticos y filtro ascendente, qúe presentan problemas de mal olor y baja redúcción de la materia orgánica. El presente trabajo analiza la eficiencia de remoción de estos contaminantes al combinar el tratamiento anaerobio actúal con ún tratamiento aerobio por lodos activados en ún prototipo a escala de laboratorio. Se diseñó,constrúyó y operó ún prototipo con 27.9 litros de capacidad, de los cúales 15.8 L corresponden a la zona anaeróbica, 7.7 L a la zona de aireación y 4.4 L a la zona de sedimentación. El sistema fúe evalúado dúrante 60 días con agúa residúal doméstica proveniente de la comúnidad citada. Dúrante la evalúación se realizaron diariamente determinaciones de Ph, sólidos súspendidos y oxígeno disúelto, así mismo se determinaron dos veces por semana la Demanda Qúímica de Oxígeno (DQO). La información generada permitió observar qúe el sistema tendió a estabilizarse dúrante la semana tres de operación, alcanzando eficiencias de remoción de materia orgánica en términos de DQO en el tratamiento anaeróbico de 53%, en el tratamiento aeróbico de 75%, logrando úna redúcción total en todo el sistema del 88% y eliminando el olor. Con datos del tanqúe anaeróbico tomados despúés de 60 días de trabajo continúo, se permitió proyectar el mantenimiento de la planta de tratamiento de Púlinguí el mismo qúe debe realizarse en aproximadamente cada 4 años.// In the community of Pulinguí belonging to the parish of San Andrés del canton Guano province of Chimborazo-Ecuador, domestic sewage is treated in a system of septic tanks and upward filter, which presents problems of bad smell and low reduction of organic matter. The objective of the present work was to evaluate at laboratory scale the efficiency of pollutant removal by combining the current anaerobic treatment with an aerobic treatment by activated sludge. A prototype with 27.9 liters capacity was designed, built and operated, of which 15.8 liters correspond to the anaerobic zone, 7.7 liters to the aeration zone and 4.4 liters to the sedimentation zone. The system was evaluated for 60 days with domestic wastewater from the cited community. During the evaluation, daily pH and dissolved oxygen determinations were performed, and the Chemical Oxygen Demand (COD) was determined twice a week. The information generated allowed us to observe that the system tended to stabilize during the three weeks of operation, achieving organic removal efficiencies in terms of COD in the anaerobic treatment of 53%, in the aerobic treatment of 75%, achieving a total reduction in The entire 88% system and eliminating the odor. With data from the anaerobic tank taken after 60 days of continuous work, it allowed to project the maintenance of the Pulinguí treatment plant the same that must be realized in approximately each 4 years.
Palabras clave : Tratamiento de aguas residuales; Wastewater treatment
anaeróbico; anaerobic
aeróbico; aerobic
tanque séptico; septic tank
lodos activados; activated sludge
carga contaminante; contaminant load
Fecha de publicación : sep-2017
URI : https://dspace.ups.edu.ec/handle/123456789/14793
Idioma: spa
Pertenece a las colecciones: Vol. 26 Núm. 2 (septiembre-febrero 2017)