Análisis espectral para la detección temprana y activación de protecciones ante fallas a tierra en redes eléctricas de media tensión con neutro aislado mediante modelado industrial

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/32497
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRuiz Maldonado, Milton Gonzalo-
dc.contributor.authorCampoverde Alvarado, Esteban Ruben-
dc.date.accessioned2026-03-24T15:02:32Z-
dc.date.available2026-03-24T15:02:32Z-
dc.date.issued2026-03-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/32497-
dc.descriptionEl presente documento se centra en el análisis espectral para la detección temprana y la activación de protecciones ante fallas a tierra en redes eléctricas de media tensión con punto neutro aislado, mediante el modelado industrial y la simulación en entornos especializados. El objetivo principal es mejorar la sensibilidad y la rapidez de detección frente a eventos de baja corriente que, por su naturaleza, no activan las protecciones convencionales. Se implementa el modelo IEEE de 13 nodos en PowerFactory 2021, adaptado para incluir cargas desequilibradas tipo PQ, transformadores con neutro sin conexión a tierra y líneas con representación capacitiva. Se simula una falla monofásica a tierra en la barra 634, y se exportan señales eléctricas al entorno MATLAB, donde se aplican técnicas de transformada wavelet continua (CWT) para calcular la energía espectral y detectar el transitorio asociado a la falla. La señal 3·u₀ demostró ser la más efectiva para la detección automática, con una respuesta clara y anticipada frente a las demás variables analizadas.spa
dc.description.abstractThis document focuses on spectral analysis for early detection and protection activation against ground faults in medium-voltage electrical networks with isolated neutral, using industrial modeling and simulation in specialized environments. The main objective is to improve detection sensitivity and response speed in low-current events that do not trigger conventional protections. The IEEE 13-bus test system is implemented in PowerFactory 2021 and adapted to include unbalanced PQ-type loads, Y–Y transformers with isolated neutrals, and lines modeled with ground capacitance. A single-phase-to- ground fault is simulated at bus 634, and electrical signals are exported to MATLAB, where continuous wavelet transform (CWT) techniques are applied to compute spectral energy and detect the transient associated with the fault. The 3·U₀ signal proved to be the most effective for automatic detection, with a clear, early response compared with the other variables analyzed.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectFALLAS DE SISTEMAS (INGENIERÍA)spa
dc.subjectENERGÍA ELÉCTRICAspa
dc.subjectREDES ELÉCTRICASspa
dc.titleAnálisis espectral para la detección temprana y activación de protecciones ante fallas a tierra en redes eléctricas de media tensión con neutro aislado mediante modelado industrialspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS2466.pdfTexto completo1,61 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons