Caracterización de la curva de consumo diario y horario de la Universidad Politécnica Salesiana Campus el Girón, Sede Quito

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/32433
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBadillo Rodríguez, Freddy Israel-
dc.contributor.authorAucay Chasiquisa, Daniela Elizabeth-
dc.contributor.authorChicaiza Reyes, Alan Sebastian-
dc.date.accessioned2026-03-18T20:36:56Z-
dc.date.available2026-03-18T20:36:56Z-
dc.date.issued2026-03-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/32433-
dc.descriptionCon el fin de identificar y registrar el consumo de agua potable dentro de la Universidad Politécnica Salesiana, campus Girón, sede Quito, en la provincia de Pichincha. Se levanto información por medio de cámaras instaladas en los cuatro puntos principales de la red de agua potable de la institución donde existen macromedidores denominados A1, A2, B1, B2, que a su vez se calculó el consumo de agua potable diario, horario y semanal durante un periodo de 42 días considerando días laborales y feriados como Fiestas de Quito, Navidad y Fin de Año, además la información recolectada se tabuló y analizó mediante gráficas y cálculos que ayudaron a reconocer patrones de consumo, días de mayor consumo como lo son días lunes, martes y miércoles, picos, valles y periodos de mayor consumo horario como es entre las 12:00 y 13:00 horas, además se calculó el consumo per cápita y los coeficientes K1 y K2 para cada macromedidor de su bloque correspondiente y la comparación con la (NEC-11) Capitulo 16, Norma Hidrosanitaria NHE Agua, dando como resultado un valor de 21 L/hab/día que está por debajo de los rangos normativos. Asimismo, el reconocimiento de la cantidad de estudiantes, personal administrativo y docentes inscritos en el Periodo 67 con un valor de 7291, además de presentar la cantidad de estudiantes para cada carrera del campus Girón y el impacto de las carreras que mayor consumo presentan dentro de la institución como lo son Derecho, Biomedicina y Odontología. Por otro lado, el análisis de presiones por medio de manómetros instalados en el campus Girón, durante un lapso de siete días permitió la identificación de presiones estáticas y dinámicas que a su vez se analizaron y tabularon para identificar el comportamiento dentro de la red de agua potable que alcanzo valores de 28,32 y 29,13 (m.c.a) para el bloque B y A respectivamente. Finalmente, los resultados permiten tener una información actualizada y real del comportamiento del consumo de agua potable que permita la mejora en la gestión del recurso hídrico y gastos o daños futuros dentro del sistema de distribución de agua potable dentro de la institución.spa
dc.description.abstractIn order to identify and record drinking water consumption within the Salesian Polytechnic University, Girón campus, Quito headquarters, in the province of Pichincha. Information was collected using cameras installed at the four main points of the institution's drinking water network, where there are macro-meters called A1, A2, B1, and B2. Daily, hourly, and weekly drinking water consumption was calculated over a period of 42 days, taking into account working days and holidays such as Quito Festivities, Christmas, and New Year's Eve. In addition, the information collected was tabulated and analyzed using graphs and calculations that helped to identify consumption patterns, days of highest consumption such as Mondays, Tuesdays, and Wednesdays, peaks, valleys, and periods of highest hourly consumption such as between 12:00 p.m. and 1:00 p.m. In addition, per capita consumption was calculated and coefficients K1 & K2 for each macro meter in its corresponding block and compared with (NEC-11) Chapter 16, Water Sanitation Standard NHE, resulting in a value of 21 L/inhabitant/day, which is below the regulatory ranges. Likewise, the number of students, administrative staff, and teachers enrolled in Period 67 was recognized with a value of 7291, in addition to presenting the number of students for each degree program at the Girón campus and the impact of the degree programs with the highest consumption within the institution, such as Law, Biomedicine, and Dentistry. On the other hand, pressure analysis using pressure gauges installed on the Girón campus over a period of seven days allowed for the identification of static and dynamic pressures, which were then analyzed and tabulated to identify behavior within the drinking water network, reaching values of 28.32 and 29.13 (m.c.a) for blocks B and A, respectively. Finally, the results provide up-to-date and accurate information on drinking water consumption behavior, allowing for improved water resource management and future expenses or damage within the institution's drinking water distribution system.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA CIVILspa
dc.subjectESTADÍSTICAspa
dc.subjectCONSUMO DE AGUA POTABLEspa
dc.subjectUNIVERSIDADESspa
dc.titleCaracterización de la curva de consumo diario y horario de la Universidad Politécnica Salesiana Campus el Girón, Sede Quitospa
dc.typebachelorThesisspa
ups.carreraIngeniería Civilspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS2433.pdfTexto completo6,35 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons