Rediseño de un Módulo Electrónico para el Control de un Sistema de Rehabilitación Motora Robótica con Emotiv Epoc
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/32154Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | Villa Parra, Ana Cecilia | - |
| dc.contributor.author | Ulloa Cabrera, Heather Pamela | - |
| dc.date.accessioned | 2026-03-03T18:06:11Z | - |
| dc.date.available | 2026-03-03T18:06:11Z | - |
| dc.date.issued | 2026-02 | - |
| dc.identifier.uri | http://dspace.ups.edu.ec/handle/123456789/32154 | - |
| dc.description | El presente trabajo tiene como finalidad diseñar y construir una segunda versión de un sistema para rehabilitación motora robótica controlada por Emotiv EPOC, con el propósito de mejorar la precisión, estabilidad y funcionalidad de la versión inicial. Para ello, se realizó una evaluación técnica y funcional del sistema previamente desarrollado, identificando fallas en la comunicación EEG–actuadores y en la estructura del módulo electrónico. A partir de estos resultados, se procedió al rediseño del sistema, incorporando mejoras electrónicas y de software que optimizan la respuesta del control cerebral hacia los actuadores robóticos. Además, se añadió una órtesis de codo al conjunto robótico, ampliando el rango de movimientos terapéuticos en extremidades superiores. Finalmente, se realizaron pruebas preliminares del nuevo sistema para validar su funcionamiento, estabilidad y adaptación a entornos de rehabilitación motora asistida, demostrando el potencial del Emotiv EPOC como herramienta accesible para aplicaciones biomédicas y terapéuticas. | spa |
| dc.description.abstract | The purpose of this work is to design and build a second version of a robotic motor rehabilitation system controlled by Emotiv EPOC, with the aim of improving the accuracy, stability, and functionality of the initial version. To this end, a technical and functional evaluation of the previously developed system was performed, identifying flaws in the EEG actuator communication and in the structure of the electronic module. Based on these results, the system was redesigned, incorporating electronic and software improvements that optimize the brain control response to the robotic actuators. In addition, an elbow orthosis was added to the robotic assembly, expanding the range of therapeutic movements in the upper extremities. Finally, tests of the new system were conducted to validate its operation, stability, and adaptation to assisted motor rehabilitation environments, demonstrating the potential of the Emotiv EPOC as an accessible tool for biomedical and therapeutic applications. | spa |
| dc.language.iso | spa | spa |
| dc.rights | openAccess | spa |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
| dc.subject | BIOMEDICINA | spa |
| dc.subject | ROBÓTICA | spa |
| dc.subject | REHABILITACIÓN NEUROLÓGICA | - |
| dc.subject | NEUROPLASTICIDAD | - |
| dc.subject | INTERFACES CEREBRO-COMPUTADOR | - |
| dc.title | Rediseño de un Módulo Electrónico para el Control de un Sistema de Rehabilitación Motora Robótica con Emotiv Epoc | spa |
| dc.type | bachelorThesis | spa |
| ups.carrera | Biomedicina | spa |
| ups.sede | Sede Cuenca | spa |
| Appears in Collections: | Grado | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| UPS-CT012606.pdf | Texto completo | 29,34 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License