Evaluación del rendimiento energético de 8 sistemas fotovoltaicos de 400W bajo diferentes condiciones de consumo

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/30931
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSantillán Carranza, Holger Jorge-
dc.contributor.authorAguilar Mayo, David Geampierre-
dc.contributor.authorCastillo Chele, Galo Xavier-
dc.date.accessioned2025-09-03T16:58:00Z-
dc.date.available2025-09-03T16:58:00Z-
dc.date.issued2025-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/30931-
dc.descriptionEste estudio evalúa el rendimiento energético real de ocho sistemas fotovoltaicos aislados de 400 W instalados en viviendas de la comunidad rural Masa II, Ecuador. A pesar de compartir configuraciones técnicas similares, los sistemas presentan variaciones significativas en su eficiencia operativa, atribuibles a factores como el perfil de consumo, las prácticas de mantenimiento y el comportamiento del usuario. Se utilizó el software VictronConnect para registrar la producción energética diaria y PVsyst para modelar el rendimiento ideal bajo condiciones climáticas locales. La comparación entre ambos conjuntos de datos permitió identificar pérdidas energéticas de hasta un 25 %, asociadas principalmente a la falta de mantenimiento preventivo y al uso desalineado con la capacidad del sistema. Los resultados refuerzan la necesidad de un enfoque integral que combine diseño técnico, capacitación continua y estrategias de monitoreo, a fin de garantizar la sostenibilidad operativa de los sistemas fotovoltaicos en comunidades rurales aisladas.spa
dc.description.abstractThis study evaluates the actual energy performance of eight stand-alone photovoltaic systems of 400 W installed in households of the rural community Masa II, Ecuador. Despite sharing similar technical configurations, the systems exhibit significant variations in operational efficiency, which are attributable to factors such as consumption profiles, maintenance practices, and user behavior. The VictronConnect software was employed to record daily energy production, while PVsyst was used to model the ideal performance under local climatic conditions. The comparison between both datasets revealed energy losses of up to 25%, mainly associated with the absence of preventive maintenance and the mismatch between usage patterns and system capacity. The findings highlight the need for a comprehensive approach that integrates technical design, continuous training, and monitoring strategies to ensure the long-term operational sustainability of photovoltaic systems in isolated rural communities.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectSISTEMAS FOTOVOLTAICOS AISLADOSspa
dc.subjectMONITOREO ENERGÉTICOspa
dc.subjectVICTRONCONNECTspa
dc.subjectPVSYSTspa
dc.subjectEFICIENCIA OPERATIVAspa
dc.subjectELECTRIFICACIÓN RURALspa
dc.titleEvaluación del rendimiento energético de 8 sistemas fotovoltaicos de 400W bajo diferentes condiciones de consumospa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Guayaquilspa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-GT006548.pdfTexto Completo787,51 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons