Seguimiento del nivel de líquido de un sistema de tanques acoplado empleando control cuasi-lpv
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/29520
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Teppa, P. | - |
dc.contributor.author | Muñoz, D. | - |
dc.contributor.author | Zambrano, J. | - |
dc.date.accessioned | 2025-02-11T22:36:03Z | - |
dc.date.available | 2025-02-11T22:36:03Z | - |
dc.date.issued | 2025-01 | - |
dc.identifier.uri | http://dspace.ups.edu.ec/handle/123456789/29520 | - |
dc.description.abstract | En este artículo se propone un procedimiento de programación de ganancias basado en un modelado cuasi-LPV de un sistema no lineal de tanques acoplados para seguir el nivel de líquido con error en estado estacionario nulo. Las no linealidades están representadas directamente por un vector de parámetros que varía dentro de un conjunto acotado por los límites físicos del nivel del sistema de tanques. Esto permite un modelado exacto del sistema no lineal utilizando un modelo lineal de parámetros variantes. Luego, se diseñan controladores lineales de realimentación de estado en los vértices extremos del conjunto acotado. El controlador global corresponde a un promedio ponderado de las contribuciones locales. Esta ponderación depende de los valores instantáneos del vector de parámetros. Para implementar el promedio ponderado de los controladores lineales, se proponen dos mecanismos de interpolación. Los resultados obtenidos muestran la efectividad del método.//This article proposes a gain-scheduling procedure based on quasi-LPV modeling for a nonlinear coupled tank system to track the liquid level with zero steadystate error. The nonlinearities are directly represented by a parameter vector that varies within a bounded set constrained by the physical limits of the tank system levels. This approach enables accurate nonlinear system modeling using a linear parameter-varying model. State-feedback linear controllers are designed at the extreme vertices of the bounded set. The global controller is derived as the weighted average of local controller contributions, with the weighting determined by the instantaneous values of the parameter vector. Two interpolation mechanisms are proposed to implement this weighted averaging of the linear controllers. The results confirm the effectiveness of the proposed method in achieving accurate liquid level tracking. | spa |
dc.language.iso | spa | spa |
dc.rights | openAccess | spa |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | sistema de tanques acoplados; Coupled-Tank System | spa |
dc.subject | programación de ganancias; Gain Scheduling | spa |
dc.subject | sistemas no lineales; Nonlinear Systems | spa |
dc.subject | cuasi-LPV; Quasi-LPV | spa |
dc.subject | problema de seguimiento; Tracking Problem | spa |
dc.title | Seguimiento del nivel de líquido de un sistema de tanques acoplado empleando control cuasi-lpv | spa |
dc.type | Article | spa |