Diseño de un controlador PID con Antiwindup para el llenado de un tanque de agua usando Simulink
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/27735
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Franco Reina, Rafael Christian | - |
dc.contributor.author | Noriega León, Marcos Hannibal | - |
dc.contributor.author | Sinche Tacuri, Eduardo Marcelo | - |
dc.date.accessioned | 2024-04-17T19:13:47Z | - |
dc.date.available | 2024-04-17T19:13:47Z | - |
dc.date.issued | 2024 | - |
dc.identifier.uri | http://dspace.ups.edu.ec/handle/123456789/27735 | - |
dc.description | El presente proyecto de tesis tiene como objetivo abordar los desafíos asociados al control de un sistema de nivel de agua en un tanque, específicamente los problemas de saturación y desbordamiento que pueden surgir en el controlador. Este trabajo, se concentra en identificar y evaluar opciones para mejorar el rendimiento del controlador, con el objetivo de mitigar la saturación y evitar el desbordamiento del nivel de agua en el tanque. La investigación se enfoca en analizar las limitaciones de los actuadores utilizados en el sistema y propone soluciones para optimizar el controlador PID mediante la técnica Anti-Windup. Para llevar a cabo este análisis, se investigó los métodos AntiWindup y se procedió a realizar la misión de diseñarlo, para ello se utilizó el programa TIA Portal para calcular el control PID y esos valores enviarlos a Simulink/Matlab mediante el software KEPServerEX, es así que, se identifica el sistema, simula e implementa el sistema de llenado de tanques para realizar una evaluación entre los métodos Antiwindup Back Calculation y Clamping con el fin de determinar el más adecuado para optimizar el sistema de control de nivel de agua en el tanque. | spa |
dc.description.abstract | The objective of this thesis project is to address the challenges associated with the control of a water level system in a tank, specifically the saturation and overflow problems that may arise in the controller. This work focuses on identifying and evaluating options to improve the performance of the controller, with the objective of mitigating saturation and avoiding overflow of the water level in the tank. The research focuses on analyzing the limitations of the actuators used in the system and proposes solutions to optimize the PID controller using the Anti-Windup technique. To carry out this analysis, the AntiWindup methods were investigated and the mission of designing it was carried out, for this the TIA Portal program was used to calculate the PID control and those values were sent to Simulink/Matlab through the KEPServerEX software, it is like this that, the system is identified, simulates and implements the tank filling system to carry out an evaluation between the Antiwindup Back Calculation and Clamping methods in order to determine the most appropriate one to optimize the water level control system in the tank. | spa |
dc.language.iso | spa | spa |
dc.rights | openAccess | spa |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | TIA PORTAL | spa |
dc.subject | CONTROLADOR PID | spa |
dc.subject | SIMULINK | spa |
dc.subject | MATLAB | spa |
dc.subject | ANTIWINDUP | spa |
dc.subject | CLAMPING | spa |
dc.title | Diseño de un controlador PID con Antiwindup para el llenado de un tanque de agua usando Simulink | spa |
dc.type | bachelorThesis | spa |
ups.carrera | Electrónica y Automatización | spa |
ups.sede | Sede Guayaquil | spa |
Pertenece a las colecciones: | Grado |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
UPS-GT005230.pdf | Texto Completo | 8,1 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons