Análisis de la variación de los parámetros de resistencia al corte en suelos de sitios de préstamo de Calderón, la Loma y Chillogallo de la ciudad de Quito, con diferentes grados de compactación y contenidos de humedad, mediante el ensayo de corte directo
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/27227
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Tarambís Rodríguez, Juan Pablo | - |
dc.contributor.author | Panata Tasgacho, Víctor Edwin | - |
dc.contributor.author | Sarzosa Bedoya, María Victoria | - |
dc.date.accessioned | 2024-03-08T21:15:23Z | - |
dc.date.available | 2024-03-08T21:15:23Z | - |
dc.date.issued | 2024-02 | - |
dc.identifier.uri | http://dspace.ups.edu.ec/handle/123456789/27227 | - |
dc.description | La investigación realizada en este artículo tiene como propósito conocer los parámetros de resistencia al corte variando el grado de compactación y contenido de humedad. Se extrajo muestras de suelo de sitios de préstamo de Calderón, la Loma y Chillogallo en estado natural (bloques inalterados) y suelo alterado, para los diferentes ensayos planteados. En los laboratorios de mecánica de suelos y geotecnia se realizó ensayos de granulometría, límites de Atterberg, densidad natural, gravedad específica, Proctor modificado variando el grado de compactación de 80%, 90% y 95%, a su vez también el contenido de humedad óptima de 95% y 101%, para determinar la cohesión y ángulo de fricción interno de cada muestra en el ensayo de corte directo. Se analizaron los resultados obtenidos, principalmente los de corte directo, para observar como varían los parámetros de resistencia al corte y brindar correctas correlaciones y conclusiones. | spa |
dc.description.abstract | The purpose of the research carried out in this article is to know the parameters of shear resistance by varying the degree of compaction and moisture content. Soil samples were extracted from Calderón, La Loma and Chillogallo loan sites in a natural state (unaltered blocks) and altered soil, for the different tests proposed. In the soil mechanics and geotechnics laboratories, the tests of granulometry, Atterberg limits, natural density, specific gravity, modified Proctor were carried out by varying the degree of compaction of 80%, 90% and 95%, in turn also the optimal moisture content of 95% and 101%, in order to then determine the parameters of cohesion and internal friction angle of each sample in the direct shear test. All the results obtained were analyzed, mainly those of direct shear, in order to observe how the shear resistance parameters vary and provide correct correlations and conclusions. | spa |
dc.language.iso | spa | spa |
dc.rights | openAccess | spa |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | INGENIERÍA CIVIL | spa |
dc.subject | ANÁLISIS ESTRUCTURAL (INGENIERÍA) | spa |
dc.subject | RESISTENCIA DE MATERIALES | spa |
dc.subject | CORTE | spa |
dc.subject | SUELOS - INVESTIGACIONES | spa |
dc.title | Análisis de la variación de los parámetros de resistencia al corte en suelos de sitios de préstamo de Calderón, la Loma y Chillogallo de la ciudad de Quito, con diferentes grados de compactación y contenidos de humedad, mediante el ensayo de corte directo | spa |
dc.type | bachelorThesis | spa |
ups.carrera | Ingeniería Civil | spa |
ups.sede | Sede Quito | spa |
Pertenece a las colecciones: | Grado |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TTS1759.pdf | Texto completo | 796,47 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons