Algoritmo de detección de fallas para motores trifásicos tipo jaula de ardilla basado en el análisis de componente principales

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/26724
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrtiz Matos, Leony-
dc.contributor.authorOrellana Pinzón, Cesar Humberto-
dc.date.accessioned2024-01-22T20:24:02Z-
dc.date.available2024-01-22T20:24:02Z-
dc.date.issued2023-01-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/26724-
dc.descriptionEn la presente investigación tiene como objetivo detectar fallas en motores trifásicos tipo jaula de ardilla, mediante el uso de un algoritmo de detección de fallos basado en Análisis de Componentes Principales en Matlab. El método se basa en el entrenamiento forzado a través de datos históricos normalizados de todas las variables medibles o registradas en un motor de inducción tipo jaula de ardilla. El estudio se realizó mediante co-simulación PLECS-Matlab, estableciendo límites de control por medio del cociente de las varianzas de los componentes principales y la distribución T² de Hotelling, proponiendo un umbral elipsoide que separa el régimen de funcionamiento normal del régimen de falla. Para el registro de datos en funcionamiento de falla se desarrolló un sistema de inyección de fallas en el esquema eléctrico del modelo del motor de inducción tipo jaula de ardilla, proponiendo tres fallas características: la excentricidad, los armónicos en el estator y la ruptura de la barra del rotor. El algoritmo se validó con el índice de falla al 10% y 90%, logrando detectar el 100% de fallas desde sus primeros índices. Además, se obtuvo los mismos resultados con datos medidos en campo.spa
dc.description.abstractThis research aims to detect faults in three-phase squirrel cage motors using a fault detection algorithm based on Principal Component Analysis in Matlab. The method is based on forced training through normalized historical data of all measurable or recorded variables in a squirrel cage induction motor. The study was performed by PLECS-Matlab co-simulation, establishing control limits through the ratio of the variances of the principal components and Hotelling’s T² distribution, proposing an ellipsoid threshold separating the normal operating regime from the fault regime. For data logging in fault operation, a fault injection system was developed on the electrical diagram of the squirrel cage induction motor model, proposing three characteristics faults: eccentricity, stator harmonics, and rotor bar breakage. The algorithm was validated with a 10% and 90% failure rate, managing to detect 100% of failures from its first rates. Furthermore, the same results were obtained with measured in the field.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectFALSOS NEGATIVOSspa
dc.subjectFALLAS DE SISTEMAS (INGENIERÍA)spa
dc.subjectREDES ELÉCTRICASspa
dc.titleAlgoritmo de detección de fallas para motores trifásicos tipo jaula de ardilla basado en el análisis de componente principalesspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS1607.pdfTexto completo2,86 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons