Comparación de mediciones de PM 2,5 y calidad de aire en la Universidad Politécnica Salesiana mediante datos obtenidos por equipo de alto volumen, un sensor de bajo costo y la Estación de Monitoreo Atmosférico de Guamaní

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/25863
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorUlloa Vaca, Carlos Andrés-
dc.contributor.authorIntriago Sandoval, Andrea Celeste-
dc.date.accessioned2023-09-25T19:40:52Z-
dc.date.available2023-09-25T19:40:52Z-
dc.date.issued2023-09-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/25863-
dc.descriptionEn la investigación presentada a continuación, se realizó la relación de comparación de datos obtenidos mediante tres métodos de monitoreo: Sensor bajo costo, High-Volumen y Estación de Monitoreo de Guamaní en la Universidad Politécnica Salesiana, Sede Quito, Campus Sur. Los puntos de Monitoreo fueron elegidos estratégicamente debido a la gran concentración vehicular y peatonal. El estudio se realizó en un periodo trimestral desde abril a junio tomando datos durante 7 horas 5 días a la semana. Por medio de este estudio se obtuvo datos como el promedio, punto medio, punto máximo, desviación estándar para posteriormente realizar las comparaciones necesarias. Tras la obtención y tratamiento de los datos por los tres métodos al realizar la Inter comparación, se pudo concluir que la concentración (ug/𝑚") de material particulado PM 2,5 detectado por la estación de Guamaní y el sensor de bajo costo instalado en la Universidad Politécnica Salesiana campus Sur son semejantes en cuento a medición de concentración de Material Particulado y de esta forma constatamos que la utilización de un sensor bajo costo es de gran ayuda para validar datos Así mismo pudimos contrastar los cambios de concentración que se evidencian dentro de los puntos de monitoreo ya sea por causas físicas, químicas o ambientales.spa
dc.description.abstractIn the present investigation, a comparison of data obtained by three low-cost sensor monitoring methods, High-Volume and Guamaní Monitoring Station at the Universidad Politecnica Salesiana, Sede Quito, Campues Sur, was carried out, the monitoring points were strategically chosen due to the high vehicular and pedestrian concentration. The study was carried out in a period of three months from April to June taking data during 7 hours 5 days a week.by means of this study we obtained data such as the average, midpoint, maximum point, standard deviation to later make the necessary comparisons.after obtaining the necessary amount of data to make the necessary comparison between the three monitoring methods and obtain the results studied. It was possible to conclude the concentration of particulate matter PM 2,5 present in the Salesian Polytechnic University and also to know which of the three methods is better in its use for future studies.likewise we could see the changes in concentration that are evident within the monitoring points either by physical, chemical or environmental causes.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA AMBIENTALspa
dc.subjectINVESTIGACIÓN CIENTÍFICAspa
dc.subjectCALIDAD DEL AIREspa
dc.subjectCONTAMINACIÓN DEL AIREspa
dc.subjectUNIVERSIDADESspa
dc.titleComparación de mediciones de PM 2,5 y calidad de aire en la Universidad Politécnica Salesiana mediante datos obtenidos por equipo de alto volumen, un sensor de bajo costo y la Estación de Monitoreo Atmosférico de Guamaníspa
dc.typebachelorThesisspa
ups.carreraIngeniería Ambientalspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS1503.pdfTexto completo1,46 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons