Análisis técnico comparativo de una torre triangular autosoportada de 42 m. de altura en el cantón Mocha, provincia de Tungurahua; utilizando la norma ANSI/TIA 222-G-2005 y ANSI/TIA 222-H-2017

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/25522
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuerrero Cuasapaz, David Patricio-
dc.contributor.authorLincango Robayo, Joel Eduardo-
dc.date.accessioned2023-08-10T21:11:00Z-
dc.date.available2023-08-10T21:11:00Z-
dc.date.issued2023-08-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/25522-
dc.descriptionA través de los años, las empresas de telecomunicaciones en Ecuador han experimentado un crecimiento vertiginoso; esto se debe a la creciente demanda de servicios de internet y telefonía en áreas donde la cobertura es ilimitada. Para satisfacer estas necesidades, las empresas están comprometidas en construir los mejores diseños de torres autosostenibles. Por tanto, este artículo académico tiene como objetivo analizar el comportamiento real de esta estructura; mediante un análisis técnico comparativo de una torre autosoportada de 42 m. de altura, utilizando la norma ANSI TIA 222-G y su versión actualizada ANSI TIA 222-H; para lo cual se generaron dos modelaciones, una por cada normativa. Esto permitió determinar aspectos de la estructura como: capacidad de carga, estabilidad estructural y resistencia a las fuerzas ambientales como son sismo y viento; este último factor es significativo, ya que es la principal causa de falla de este tipo de estructuras. Es importante destacar que se mantuvo la misma geometría, configuración y material en ambas estructuras para realizar una comparación precisa. Los resultados obtenidos indicaron que el criterio de la Norma ANSI TIA 222-H, es óptimo para el diseño y construcción de la torre estudiada; este criterio permite un consumo mínimo de material y una mayor resistencia a las cargas actuantes; además los resultados revelaron que la Norma ANSI TIA 222-H reduce más del 50 % las fuerzas, deflexiones, reacciones y momentos en comparación con la Norma ANSI TIA 222-G.spa
dc.description.abstractOver the years, telecommunication companies in Ecuador have experienced dizzying growth; this is due to the increasing demand for internet and telephony services in areas where coverage is unlimited. To meet these needs, companies are committed to building the best self-sustainable tower designs. Therefore, the objective of this academic paper is to analyze the real behavior of this structure; through a comparative technical analysis of a 42 m. high self-supported tower, using the ANSI TIA 222-G standard and its updated version ANSI TIA 222-H; for which two modeling’s were generated, one for each standard. This allowed determining aspects of the structure such as: load capacity, structural stability and resistance to environmental forces such as seismic and wind; this last factor is significant, since it is the main cause of failure of this type of structures. It is important to note that the same geometry, configuration and material were maintained in both structures in order to make an accurate comparison. The results obtained indicated that the ANSI TIA 222-H criterion is optimal for the design and construction of the tower studied; this criterion allows a minimum consumption of material and a greater resistance to the acting loads; furthermore, the results revealed that the ANSI TIA 222-H Standard reduces forces, deflections, reactions and moments by more than 50% compared to the ANSI TIA 222-G Standard.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA CIVILspa
dc.subjectANÁLISIS COMPARATIVOspa
dc.subjectANÁLISIS ESTRUCTURALspa
dc.subjectESTRUCTURAS METÁLICASspa
dc.subjectTELECOMUNICACIONESspa
dc.titleAnálisis técnico comparativo de una torre triangular autosoportada de 42 m. de altura en el cantón Mocha, provincia de Tungurahua; utilizando la norma ANSI/TIA 222-G-2005 y ANSI/TIA 222-H-2017spa