Determinación de un factor de incremento porcentual para el diseño de cimentaciones aisladas bidireccional, a través del método uniaxial equivalente en viviendas unifamiliares aporticadas

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/25300
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorArévalo Navarrete, Marlon Manolo-
dc.contributor.authorChipantasi Chipantasi, Luis Fernando-
dc.contributor.authorArmijos Andagoya, Kleber Jefferson-
dc.date.accessioned2023-08-01T14:38:06Z-
dc.date.available2023-08-01T14:38:06Z-
dc.date.issued2023-07-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/25300-
dc.descriptionEn esta investigación se realizó el análisis estadístico de los valores obtenidos del diseño a flexión biaxial para los distintos casos de cimentaciones aisladas propuestas, con la finalidad de encontrar un factor de incremento porcentual equivalente entre los momentos analizados, que pueda ser empleado para simplificar el procedimiento de diseño a flexión biaxial como un caso de flexión uniaxial [1]. Con un software estructural se realizó un análisis sísmico dinámico tomando en consideración los valores representativos de la ciudad de Quito, para una edificación de dos pisos de altura, estimada para la utilización de una vivienda unifamiliar configurada como una estructura aporticada con vigas peraltadas, esto con la finalidad de obtener las cargas axiales y momentos en dos direcciones que actúan en la base de la estructura y emplear un software para el análisis de las cimentaciones. Finalmente, utilizando una distribución normal con los datos recopilados de los programas empleados, se determinó un factor de incremento porcentual que se empleará sobre el momento flexionante para el diseño uniaxial.spa
dc.description.abstractIn this research, a statistical analysis of the values obtained from the biaxial bending design for the different cases of proposed isolated foundations was performed, with the purpose of finding an equivalent percentage increase factor between the analyzed moments, which can be used to simplify the biaxial bending design procedure as a uniaxial bending case [1]. A dynamic seismic analysis was performed with a structural software, considering the representative values of the city of Quito, for a two-story building, estimated for the use of a single-family house configured as a portal frame structure with cambered beams, in order to obtain the axial loads and moments in two directions acting on the base of the structure and to use a software for the analysis of the foundations. Finally, using a normal distribution with the data collected from the programs used, a percentage increase factor to be used on the bending moment for the uniaxial design was determined.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA CIVILspa
dc.subjectESTADÍSTICAspa
dc.subjectDISEÑO EN INGENIERÍAspa
dc.subjectCIMENTACIONESspa
dc.subjectSOFTWARE DE APLICACIÓNspa
dc.titleDeterminación de un factor de incremento porcentual para el diseño de cimentaciones aisladas bidireccional, a través del método uniaxial equivalente en viviendas unifamiliares aporticadasspa
dc.typebachelorThesisspa
ups.carreraIngeniería Civilspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS1342.pdfTexto completo914,87 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons