Óptimo control de frecuencia aplicado a una micro-red eólica con generadores de inducción doblemente alimentados usando el algoritmo de Harris Hawks

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/24056
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBarrera Singaña, Carlos Andrés-
dc.contributor.authorCumbal Hernández, Erick Andrés-
dc.date.accessioned2023-01-18T22:40:09Z-
dc.date.available2023-01-18T22:40:09Z-
dc.date.issued2023-01-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/24056-
dc.descriptionLos límites del rango real de la variación de frecuencia (Δf) en los sistemas eléctricos de potencia (SEP), su objetivo es obtener valores llegando al rango ideal es decir 60 Hz después de haber sufrido alguna perturbación, es por esto, por lo que en el presente documento se pretende optimizar el control de los generadores de inducción doblemente alimentados los cuales forman la micro-red, dicho control será el encargado en el balance de la generación y la demanda. Las restricciones del modelo de optimización de Harris Hawks analizan los valores de la velocidad síncrona de las máquinas haciendo referencia a esta como el halcón estimando así su aceleración o desaceleración con el fin de dar respuesta a la demanda del sistema (conejo), que en cierto tiempo de simulación se provocó un cortocircuito trifásico en una L/T y adicional a eso las cargas tenían un incremento del 0.05[%], brindado datos favorables y cumpliendo con la función objetivo la cual es minimizar la variación de frecuencia.spa
dc.description.abstractThe limits of the real range of the frequency variation (Δf) in the power electrical systems, its objective is to obtain values reaching the ideal range that is 60 Hz after having suffered some disturbance, that is why, in the present document it is intended to optimize the control of the doubly-fed induction generators which form the micro-grid, this control will be in charge of the generation and demand balance. The restrictions of the Harris Hawks optimization model analyze the values of the synchronous speed of the machines making reference to this as the hawk thus estimating its acceleration or deceleration in order to respond to the demand of the system (rabbit), that in certain simulation time a three-phase short circuit was caused in a L/T and in addition to that the loads had an increase of 0.05[%], providing favorable data and complying with the objective function which is to minimize the frequency variation.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.subjectENERGÍA EÓLICAspa
dc.titleÓptimo control de frecuencia aplicado a una micro-red eólica con generadores de inducción doblemente alimentados usando el algoritmo de Harris Hawksspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS1118.pdfTexto completo3,18 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons