Evaluación del sistema de floculación de la planta de tratamiento “Paluguillo

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/23873
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSoria Pugo, María Gabriela-
dc.contributor.authorPillajo Correa, Roberto Carlos-
dc.date.accessioned2022-11-30T14:03:41Z-
dc.date.available2022-11-30T14:03:41Z-
dc.date.issued2022-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/23873-
dc.descriptionEl presente trabajo desarrollado en la Planta de Tratamiento “Paluguillo”, ubicada en el nororiente de la Ciudad de Quito, Provincia de Pichincha, está encaminado a evaluar el Sistema de Floculación de dicha planta, la cual presenta problemas para procesar más de 530 l/s dicha planta está diseñada para procesar 600 l/s, la planta de tipo convencional con procesos de mezcla rápida, floculación, sedimentación, filtración, y desinfección. Capta el agua cruda proveniente del sistema de Aducción Papallacta. Como parte del estudio de la planta se realiza un análisis estadístico con los datos de color y turbiedad, recopilados de los archivos de la Planta del año 2018 hasta el 2021, para determinar la probabilidad de ocurrencia. La finalidad de este trabajo es determinar el funcionamiento hidráulico del sistema de floculación, la prueba se lo realiza con la ayuda de trazadores, donde se evalúa: el tipo de flujo que se presenta en cada unidad, zonas muertas, cortocircuitos y el tiempo de retención. Los resultados de esta evaluación del sistema de tratamiento, servirá como información para decidir cuáles son las mejoras posibles de la eficiencia del sistema y realizar un proyecto de mejoramiento de los floculadores de la Planta de Tratamiento.spa
dc.description.abstractThis work developed at the "Paluguillo" treatment plant, located in the city of Quito, Pichincha province, aims to evaluate the purification system of the plant, which presents problems to process more than 530 l/s said plant is designed to process 600 l/s, the conventional type plant with rapid mixing, flocculation, sedimentation, filtration, and disinfection processes. It captures the raw water adduction Papallacta system. As part of the study of the plant is performed a statistical analysis with the data of color and turbidity, collected from the archives of the plant of the year 2018 to 2021, to determine the probability of occurrence. The purpose of this work is to determine the hydraulic performance of treatment units: fast mixing, flocculation and settler, the test is it performed with the help of tracers, where is evaluated: the type of flow that occurs in each unit, dead zones, and shorts. The results of this evaluation of the treatment system, will serve as information to decide what improvements are possible the efficiency of the system and carry out a project of improvement of the treatment plant.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectRECURSOS HÍDRICOSspa
dc.subjectPLANTA CONVENCIONALspa
dc.subjectANÁLISIS ESTADÍSTICOspa
dc.subjectSISTEMA DE FLOCULACIÓNspa
dc.titleEvaluación del sistema de floculación de la planta de tratamiento “Paluguillospa
dc.typemasterThesisspa
ups.carreraMaestría en Recursos Hídricosspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Posgrado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
MSQ467.pdfTexto completo1,58 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons