Reducción del desequilibrio de voltaje mediante el uso del interruptor de transferencia estática, en una micro-red

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/23319
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrizondo Martínez, Rogelio Alfredo-
dc.contributor.authorCampoverde Flores, Dayana Mariyith-
dc.date.accessioned2022-09-14T17:11:09Z-
dc.date.available2022-09-14T17:11:09Z-
dc.date.issued2022-09-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/23319-
dc.descriptionEn el presente artículo se plantea el modelo de una micro-red bipolar desequilibrada en corriente continua. Se presentan los resultados de un conjunto de maniobras la cual tiene como objetivo reducir el desbalance de voltaje y por ende minimizar las pérdidas de potencia usando los interruptores de transferencia estática STS. Para el desarrollo de este artículo se tomó en cuenta la simulación de la micro-red original sin generación distribuida GD y la micro-red con GD. Todos los casos de estudio fueron simulados en el software ATP Draw. En ambos casos se analiza el desbalance de voltaje con y sin el uso de los interruptores, en el nodo más alejado de la micro-red para observar la diferencia de voltajes entre ellos. Los resultados obtenidos en el presente artículo se lograron con la correcta ubicación de los interruptores STS la reducción de pérdidas de potencia, desbalance de voltaje cumpliendo con el rango límite del porcentaje de desbalance %VU entre líneas y por ende reduciendo la caída de voltaje en cada una de las líneas.spa
dc.description.abstractIn this article, the model of an unbalanced bipolar micro-network in direct current is proposed. The results of a set of maneuvers are presented which aims to reduce voltage unbalance and therefore minimize power losses using static transfer switches STS. For the development of this article, the simulation of the original micro-grid without distributed generation DG and the micro-grid with DG was taken into account. All study cases were simulated in the ATP Draw software. In both cases, the voltage unbalance is analyzed with and without the use of the switches, in the furthest node of the micro-network to observe the voltage difference between them. The results obtained in this article were achieved with the correct location of the switches STS, the reduction of power losses, voltage imbalance, complying with the limit range of the percentage of imbalance %VU between lines and therefore reducing the drop. voltage on each line.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectFUERZA ELECTROMOTRIZspa
dc.subjectTRANSFERENCIA DE ENERGÍAspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.titleReducción del desequilibrio de voltaje mediante el uso del interruptor de transferencia estática, en una micro-redspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS955.pdfTexto completo2,32 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons