Diseño de la planta de tratamiento de agua residual mediante lodos activados para la Comunidad de Pesillo, parroquia Olmedo

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19898
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSánchez Proaño, Renato Gabriel-
dc.contributor.authorArciniega Tenemaza, Andrés Eduardo-
dc.contributor.authorSalazar Chacha, Johanna Patricia-
dc.date.accessioned2021-03-07T22:58:09Z-
dc.date.available2021-03-07T22:58:09Z-
dc.date.issued2021-03-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/19898-
dc.descriptionEl presente trabajo de investigación tiene como finalidad proponer un sistema de tratamiento de aguas residuales de los efluentes provenientes de la comunidad de Pesillo, parroquia Olmedo, esto con el fin de dar solución a la problemática actual de contaminación del recurso agua debido a que es un problema colectivo por el hecho de que demás comunidades aguas abajo utilizan la misma corriente de agua para actividades de riego, abrevaderos, etc. Para conocer si el tratamiento propuesto sería el adecuado para el tipo de agua residual de Pesillo se determinó primero el índice de biodegradabilidad, del cual se obtuvo un índice promedio de 0,41 estableciendo de manera concisa que el tratamiento biológico mediante lodos activados propuesto en la presente investigación queda acorde al tipo de agua residual a tratar. Al ser un agua residual domestico a tratar se aplicó un muestreo compuesto durante una semana consiguiendo conocer las características reales que tiene el agua residual, con los análisis obtenidos se procedió a dimensionar la PTAR generando el diseño de las unidades acorde a su tipo de agua residual, población futura y caudal. Así también como parte de la investigación se realizó la prueba de tratabilidad a escala de laboratorio con lodos activados para conocer las tasas de lodos, para ello se aireó durante 24 horas para asegurar que el sistema se mantenga aerobio durante la prueba. Consiguiendo así que el parámetro de DQO bajara de 1101 mg/L a 117 mg/L. Las dimensiones de las unidades de tratamiento se utilizaron para efectuar el diseño del esquema general de la PTAR para la comunidad de Pesillo, en los planos se visualiza el canal de ingreso, la criba, trampa de grasas, sedimentador primario y secundario, tanque aireador, tanque de cloración y el lecho de secado.spa
dc.description.abstractThe purpose of this research work is to propose a wastewater treatment system effluent of the Pesillo community, Olmedo parish, this in order to solve the current problem pollution of the water resource because it is a collective problem due to the fact that other communities downstream use the same stream of water for irrigation activities, watering holes, etc. In order to know whether the proposed treatment would be appropriate for the type of wastewater of Pesillo, the biodegradability index was first determined, of which an average rate of 0.41 was obtained by concisely establishing that biological treatment by activated sludge proposed in this research is in line with the type of wastewater to be treated. Being a domestic wastewater to be treated, a composite sampling was applied for a week getting to know the real characteristics of wastewater, with the analyses obtained, the PTAR was sized generating the design of the units according to their type of wastewater, future population and flow. As well as part of the research, laboratory-scale treatability testing was performed with sludge activated to know sludge rates, to do this, it was aerated for 24 hours to ensure that the system remains aerobic during the test. Thus, the COD parameter will drop from 1101 mg/L to 117 mg/L. The dimensions of the treatment units were used to design the general schema of the PTAR for the Pesillo community, the planes display the ingress channel, screen, grease trap, primary and secondary sedimentator, aerator tank, chlorination tank and the drying bed.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA AMBIENTALspa
dc.subjectDISEÑO EN INGENIERÍAspa
dc.subjectPLANTAS PARA TRATAMIENTO DE AGUAS RESIDUALESspa
dc.subjectAGUAS RESIDUALES - PURIFICACIÓNspa
dc.subjectLODOS ACTIVADOSspa
dc.titleDiseño de la planta de tratamiento de agua residual mediante lodos activados para la Comunidad de Pesillo, parroquia Olmedospa
dc.typebachelorThesisspa
ups.carreraIngeniería Ambientalspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS292.pdfTexto completo5,65 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons