Humedad y su relación con la espectroscopía dieléctrica en agregados de concreto
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/18841
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Abanto, Franco | - |
dc.contributor.author | Rotta, Pedro | - |
dc.contributor.author | LaMadrid, Luis | - |
dc.contributor.author | Soto, Juan | - |
dc.contributor.author | La Rosa, Gerson | - |
dc.contributor.author | Manrique, José | - |
dc.contributor.author | Ruiz, Gaby | - |
dc.contributor.author | Ipanaque, William | - |
dc.date.accessioned | 2020-07-28T01:12:01Z | - |
dc.date.available | 2020-07-28T01:12:01Z | - |
dc.date.issued | 2020-07 | - |
dc.identifier.uri | https://dspace.ups.edu.ec/handle/123456789/18841 | - |
dc.description.abstract | Medir el contenido de humedad (CH) de los agregados de concreto (ADC) en la fabricación de concreto premezclado es uno de los retos en la industria de la construcción porque afecta a las propiedades finales del concreto. Actualmente los métodos que se utilizan para medir el CH en ADC son invasivos y destructivos. Este artículo presenta una técnica moderna basada en espectroscopía dieléctrica (ED), un método que al propagar microondas en el material correlaciona su constante dieléctrica (CD) y su CH. En esta investigación se ha utilizado este método en ADC. Tres diferentes canteras peruanas de ADC (Moyobamba, Sol-Sol y Cerro Mocho) han sido utilizadas. Los resultados demuestran que el sensor a una frecuencia de 1.5 GHz es capaz de detectar el CH en ADC con una regresión lineal de R2 = 95 %. En conclusión, se puede utilizar la ED como un método de sensado no invasivo y en línea de CH en ADC para ser utilizado en la industria de la construcción.//Measurement of moisture content (CH) of concrete aggregates (AOC) in the manufactury of ready mixed concrete is one of the currently challenges in the building industry since affect to the final properties of concret. At present, the methods for measurement of CH in AOC are invasive and destructive. This paper presents a novel sensing technique using dielectric espectroscopy (ED), a method that using the propagation of microwaves on the material allows the correlation of its dielectric constant (CD) and its CH. In this research is used this method in AOC. Three diferents peruvian quarries (Moyobamba, Sol sol y Cerro Mocho) have been used. The results shows that the sensor at the frequency of 1.5GHz is capable of detecting the CH in AOC with linear regression of R2 = 95%. In conclusion, is available using the ED as a online and no invasive sensing method of CH in AOC for using in the building industry. | spa |
dc.language.iso | spa | spa |
dc.rights | openAccess | spa |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | contenido de humedad; moisture contentent | spa |
dc.subject | microondas; microwaves | spa |
dc.subject | espectroscopía dieléctrica; dielectric spectroscopy | spa |
dc.subject | constante dieléctrica; dielectric contant | spa |
dc.subject | agregados de concreto; concrete aggregates | spa |
dc.title | Humedad y su relación con la espectroscopía dieléctrica en agregados de concreto | spa |
dc.type | Article | spa |
Pertenece a las colecciones: | Núm. 24 (julio-diciembre 2020) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ings_v24_Abanto_Rotta_LaMadrid_Soto_La Rosa_Manríquez_Ruiz_Ipanaque.pdf | 1,08 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons