Ubicación de fallas en líneas de transmisión eléctrica basado en el análisis de señales transitorias

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18806
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRuiz Maldonado, Milton Gonzalo-
dc.contributor.authorRivera Mayo, Gabriela Nathaly-
dc.date.accessioned2020-07-21T04:52:40Z-
dc.date.available2020-07-21T04:52:40Z-
dc.date.issued2020-07-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18806-
dc.descriptionUna técnica que permita la ubicación rápida y precisa de diversos tipos de falla a lo largo de las líneas de transmisión y la importancia de tal ubicación se aborda en el presente trabajo, esto se realiza por medio del análisis de las señales que se presentan inmediatamente después de la ocurrencia por medio de la técnica de transformada de Wavelet discreta. Para ello se obtienen los coeficientes de detalle de las señales de voltaje y de corriente según sea el caso, ensayando diversas Wavelets madre para encontrar aquella que permite un cálculo de la distancia de falla con el menor error porcentual. Se analiza un sistema tipo IEEE de 39 barras que se compone de líneas cortas, medias y largas de tal forma de realizar un análisis de las ventajas y limitaciones de la metodología propuesta, así como los aspectos que deben ser considerados para resultados precisos de la distancia de falla incluyendo el cálculo de la velocidad de propagación, la elección del modo de cálculo y elecciones que son propias de cada línea y sus características inherentes. Se propone también el uso de la transformada de Clarke que permite realizar un análisis modal de los eventos de falla.spa
dc.description.abstractA technique that allows the fast and precise location of various types of failure along transmission lines and the importance of such location is addressed in this work, this is done by analyzing the signals that occur immediately after of the occurrence by means of the discrete Wavelet transform technique. For this, the detail coefficients of the voltage and current signals are obtained, as the case may be, testing various mother Wavelets to find the one that allows a calculation of the fault distance with the least percentage error. An IEEE type system of 39 bars is analyzed, which is made up of short, medium and long lines in order to carry out an analysis of the advantages and limitations of the proposed methodology, as well as the aspects that must be considered for accurate distance results. of failure including the calculation of the propagation speed, the choice of the calculation mode and choices that are specific to each line and their inherent characteristics. The use of the Clarke transform is also proposed, which allows a modal analysis of failure events.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectTRANSMISIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICA - CONTROLspa
dc.subjectFRECUENCIA DE OSCILACIÓN DE SISTEMASspa
dc.subjectLÍNEAS ELÉCTRICASspa
dc.titleUbicación de fallas en líneas de transmisión eléctrica basado en el análisis de señales transitoriasspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS017.pdfTexto completo4,15 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons