Modelo Gaussiano t-student como método para evaluar el consumo eléctrico en sectores comerciales de acuerdo a la arquitectura bioclimática para alcanzar zonas óptimas de confort

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18568
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCuji Cuji, Cristian Cristóbal-
dc.contributor.authorSisa Sandoval, Henry David-
dc.date.accessioned2020-03-12T15:51:45Z-
dc.date.available2020-03-12T15:51:45Z-
dc.date.issued2020-02-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18568-
dc.descriptionLa presente investigación realiza una descripción del efecto del consumo de energía eléctrica en ambientes normales, aprovechando las condiciones bioclimáticas con el objetivo de alcanzar condiciones óptimas de confort. Se propone el modelo Gaussiano T-Student como método para evaluar el consumo eléctrico, estimando la frecuencia de trabajo de aire acondicionado, en condiciones de temperatura, humedad relativa y velocidad del viento desde el 8 de septiembre del 2018 hasta el 8 de septiembre del 2019 de las ciudades Quito y Guayaquil. La idea clave es combinar el conocimiento previo del modelo ASHRAE como método para el análisis de arquitectura bioclimática por ganancias de energía térmicas para luego estimar el efecto de temperatura de sensación interna que produce. Los resultados del consumo eléctrico se obtendrán del sector comercial para satisfacer las necesidades de confort por medio de condiciones óptimas de confort de arquitectura bioclimática y consumo eléctrico en un entorno simulado, aplicables a diferentes escenarios.spa
dc.description.abstractThe present investigation makes a description of the effect of the consumption of electric energy in normal environments, taking advantage of the bioclimatic conditions with the objective of achieving optimal comfort conditions. The Gaussian T-Student model is proposed as a method to evaluate the electrical consumption, estimating the working frequency of air conditioning, in conditions of temperature, relative humidity and wind speed from September 8, 2018 to September 8, 2019 from the cities Quito and Guayaquil. The key idea is to combine prior knowledge of the ASHRAE model as a method for the analysis of bioclimatic architecture by thermal energy gains and then estimate the effect of internal sensation temperature it produces. The results of the electricity consumption will be obtained from the commercial sector to meet the needs of comfort through optimal conditions of comfort of bioclimatic architecture and electrical consumption in a simulated environment, applicable to different scenarios.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectCONSUMO DE ENERGÍA ELÉCTRICAspa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICAspa
dc.subjectREDES ELÉCTRICASspa
dc.titleModelo Gaussiano t-student como método para evaluar el consumo eléctrico en sectores comerciales de acuerdo a la arquitectura bioclimática para alcanzar zonas óptimas de confortspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - ST004496.pdfTexto completo1,73 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons