Influencia del factor de reducción de resistencia sísmica (R) en edificaciones, utilizando los sistemas constructivos: Dual losas postensadas-muros y tradicional

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18219
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGuerrero Cuasapaz, David Patricio-
dc.contributor.authorLasso Martínez, Luis Fidel-
dc.contributor.authorPillajo Tello, Luis Sebastián-
dc.date.accessioned2020-01-08T21:59:35Z-
dc.date.available2020-01-08T21:59:35Z-
dc.date.issued2020-01-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18219-
dc.descriptionSe presenta un análisis de catorce modelos estructurales de los cuales siete corresponden a edificaciones de hormigón armado y siete a edificaciones con sistema dual de losas postensadas y muros de corte, modelados y analizados a partir de las herramientas computacionales ETABS-2016 y SAFE12. Se sometió a las estructuras a un análisis estático lineal considerando el cumplimiento de los controles establecidos en la norma NEC-SE-DS, 2015 garantizando un adecuado comportamiento sismo-resistente en las mismas. Además, se realizó un análisis no lineal, obteniendo la curva de capacidad de las estructuras, con el fin de determinar parámetros que permitan calcular el Factor de Reducción de Resistencia Sísmica (R) en cada modelo. Los resultados del factor R fueron obtenidos a partir de varios métodos vigentes y comparados con lo tabulado en norma, llegando a determinar que la media de los valores para el caso del sistema de pórticos de hormigón armado es 6.01, mientras que, para el caso del sistema dual de losas postensadas y muros de corte es 6.66, es decir 24.86% y 16.77% menor a lo considerado en norma, correspondientemente.spa
dc.description.abstractAn analysis of fourteen structural models is presented, seven of which correspond to reinforced concrete buildings and seven to buildings with dual system of post-tensioned slabs and cutting walls, modeled and analyzed from the tools ETABS-2016 and SAFE12. The structures were subjected to a linear static analysis considering compliance with the controls set out in the NEC-SE-DS standard, 2015 ensuring adequate seismic-resistant behavior in them. In addition, a nonlinear analysis was performed, obtaining the capacity curve of the structures, in order to determine parameters that allow to calculate the Seismic Resistance Reduction Factor (R) in each model. The results of the R-factor were obtained from several methods in force and compared to the norm, going so far as to determine that the mean of the values for the case of the reinforced concrete porch system is 6.01, while, for that case of the dual system of post-tensioned slabs and cutting walls is 6.66, that is 24.86% and 16.77% lower than considered in the norm, correspondingly.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA CIVILspa
dc.subjectANÁLISIS ESTRUCTURAL (INGENIERÍA)spa
dc.subjectDISEÑO SISMORRESISTENTEspa
dc.subjectCONSTRUCCIÓNspa
dc.subjectEDIFICIOSspa
dc.subjectDISEÑO ESTRUCTURALspa
dc.subjectLOSASspa
dc.titleInfluencia del factor de reducción de resistencia sísmica (R) en edificaciones, utilizando los sistemas constructivos: Dual losas postensadas-muros y tradicionalspa
dc.typebachelorThesisspa
ups.carreraIngeniería Civilspa
ups.sedeSede Quitospa