Evaluación de la coordinación de reconectador - fusible debido a la interconexión de generación emergente

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18121
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorValenzuela Santillán, Alex David-
dc.contributor.authorGodoy Cárdenas, Joshua David-
dc.date.accessioned2019-11-30T20:26:09Z-
dc.date.available2019-11-30T20:26:09Z-
dc.date.issued2019-12-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18121-
dc.descriptionEl artículo realiza la evaluación de la coordinación de reconectador –fusible debido a la interconexión de generación emergente, dado que en los sistemas de distribución al existir el ingreso de generación se produce cambios en las corrientes de flujo de potencia y de cortocircuito teniendo como resultado que las protecciones no coordinen de manera selectiva y eficaz. El análisis de los dos casos de sistemas de distribución es realizado para determinar el funcionamiento inicial tanto del flujo de potencia, así como la coordinación de protecciones. Con los resultados de los casos iniciales, se procede a la ubicación óptima de los generadores emergentes, tomando como parámetro principal la minimización de pérdidas de potencia debido a los elementos y la estructura del sistema aplicando métodos meta heurísticos, la misma que es resuelta mediante el programa MATLAB y posteriormente se actualiza los estudios eléctricos de flujo de potencia, análisis de cortocircuito y coordinación de protecciones por medio del software ETAP y se realiza la evaluación de la coordinación de protecciones y las soluciones para mejorar el sistema para que sea capaz de funcionar en los dos escenarios propuestos.spa
dc.description.abstractThe article performs the evaluation of the function of recloser - fuse due to the interconnection of emergent generation, since in the distribution systems when the generation income exists there are changes in the power flow currents and short circuit as a result that the result Uncoordinated protections selectively and effectively. The two cases of analysis of distribution systems are analyzed to determine the initial operation as well as the power flow, as well as the coordination of protections. With the results of the initial cases, they are derived from the location of the emergent generators, as well as from the main function of minimizing the advantages of the enhancement of the frozen elements, the same that is solved in the MATLAB program and then the electrical studies of power flow, short circuit analysis and coordination of protections in the ETAP software medium and in the evaluation of the coordination of protections and solutions to improve the system so that the sea is capable of functioning are updated proposed scenarios.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectAPARATOS E INSTRUMENTOS ELECTRÓNICOS - PROTECCIÓNspa
dc.subjectFUSIBLESspa
dc.subjectSISTEMAS DE INTERCONEXIÓN ELÉCTRICAspa
dc.subjectPRODUCCIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.titleEvaluación de la coordinación de reconectador - fusible debido a la interconexión de generación emergentespa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - ST004383.pdfTexto completo3 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons