Corrección de simetría de corrientes en redes eléctricas de distribución mediante óptima conexión de transformadores monofásicos empleando búsqueda exhaustiva
Para citar o enlazar este item, por favor use el siguiente identificador:
http://dspace.ups.edu.ec/handle/123456789/18065
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Aguila Téllez, Alexander | - |
dc.contributor.author | Cruz Aquieta, Alex Santiago de la | - |
dc.date.accessioned | 2019-11-21T14:31:48Z | - |
dc.date.available | 2019-11-21T14:31:48Z | - |
dc.date.issued | 2019-11 | - |
dc.identifier.uri | https://dspace.ups.edu.ec/handle/123456789/18065 | - |
dc.description | Este documento presenta un modelo de reconexión de transformadores monofásicos (TrM) a lo largo de una red trifásica real de un sistema de distribución predominante de cargas residenciales, obteniendo un porcentaje mínimo de desbalance de corriente, mediante una combinación de las cargas entre las tres fases del sistema, realizado por un modelo de optimización en el programa computacional Matlab conjuntamente con GAMS en el cual se emplea el método de búsqueda exhaustiva. Este modelo de optimización permite repartir los TrM en las tres fases del sistema (A, B, C) de manera balanceada minimizando la diferencia entre la potencia que asume cada línea, por ende, si las cargas se distribuyen de manera simétrica, lo mismo sucederá con las corrientes de tal manera que se cumple con el objetivo de reducir el porcentaje de balance de corrientes. Para evidenciar los resultados obtenidos, se realiza la simulación en el programa computacional DIgSILENT PowerFactory del cual se obtiene valores de corriente con la conexión actual de los TrM y se compara con los valores obtenidos luego de haber aplicado la reconexión planteada. | spa |
dc.description.abstract | This document presents a reconnection model of single-phase transformers (SPT) along a real three-phase network of a predominant distribution system of residential loads, obtaining a minimum percentage of current imbalance, by means of a combination of the loads between the three phases of the system, carried out by an optimization model in the Matlab computer program together with GAMS, in which the exhaustive search method is used. This optimization model allows to distribute the SPT in the three phases of the system (A, B, C) in a balanced way, minimizing the difference between the power assumed by each line, then, if the loads are distributed symmetrically, the same will happen with the currents in such a way that the objective of reducing the current balance percentage is fulfilled. To demonstrate the results obtained, the simulation is performed in the DIgSILENT PowerFactory computer program from which current values are obtained with the current connection of the SPT and compared with the values obtained after having applied the proposed reconnection. | spa |
dc.language.iso | spa | spa |
dc.rights | openAccess | spa |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | * |
dc.subject | INGENIERÍA DE SISTEMAS | spa |
dc.subject | RECTIFICADORES DE CORREINTE ELÉCTRICA | spa |
dc.subject | REDES ELÉCTRICAS | spa |
dc.subject | DISTRIBUCIÓN DE ENERGÍA ELÉCTRICA | spa |
dc.subject | TRANSFORMADORES ELÉCTRICOS | spa |
dc.subject | BÚSQUEDA Y CORRECCIÓN DE ERRORES (COMPUTACIÓN) | spa |
dc.title | Corrección de simetría de corrientes en redes eléctricas de distribución mediante óptima conexión de transformadores monofásicos empleando búsqueda exhaustiva | spa |
dc.type | bachelorThesis | spa |
ups.carrera | Ingeniería Eléctrica | spa |
ups.sede | Sede Quito | spa |
Pertenece a las colecciones: | Grado |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
UPS - ST004377.pdf | Texto completo | 1,7 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons