Configuración óptima del flujo de potencia DC frente a contingencias n-2

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/17529
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrizondo Martínez, Rogelio Alfredo-
dc.contributor.authorGualoto Loachamín, Gerson Adrián-
dc.date.accessioned2019-07-19T16:39:12Z-
dc.date.available2019-07-19T16:39:12Z-
dc.date.issued2019-07-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/17529-
dc.descriptionEn este documento se presenta la optimización del flujo de potencia cuando el sistema presente contingencias N-2, las cuales son causadas por condiciones atmosféricas o fallas en cualquier elemento del Sistema Eléctrico de Potencia (SEP) provocando que los niveles de voltaje, corriente y frecuencia se vean afectados en relación a los valores nominales de operación. Mediante la optimización del flujo óptimo linealizado DC se minimiza los costos de operación del SEP sujetos a restricciones de capacidades de generadores y límites de potencia en las líneas. Esto con el fin de brindar mayor confiabilidad al servicio eléctrico. Para el desarrollo del problema se realiza un programa en el software GAMS el cual ejecuta un despacho económico con la función objetivo de costos y restricciones antes mencionadas. El análisis se lo realiza en dos casos distintos es decir, primero, cuando el sistema eléctrico opera en condiciones normales; segundo, cuando el sistema se encuentra frente a una contingencia N-2. Se toma como base el modelo IEEE de 30 barras para realizar el análisis.spa
dc.description.abstractThis document presents the optimization of the power flow when the system presents N-2 contingencies, which are caused by atmospheric conditions or failures in any element of the electrical power system (SEP) causing the levels of Voltage, current and frequency are affected in relation to the nominal operating values. By optimizing the optimal flow, linearized DC minimizes the operating costs of the SEP subject to constraints of generator capacities and power limits on the lines. This in order to provide greater reliability to the electrical service. For the development of the problem, a program is carried out in the GAMS software that executes an economic dispatch with the objective function of costs and restrictions mentioned above. The analysis is carried out in two different cases i.e., first, when the electrical system operates under normal conditions; Second, when the system is in front of an N-2 contingency. It is based on the 30-bar IEEE model to perform the analysis.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectELECTRÓNICA DE POTENCIAspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectCAPACITANCIAspa
dc.titleConfiguración óptima del flujo de potencia DC frente a contingencias n-2spa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa