Coordinación autimática de protecciones de distancia en líneas de transmisión frente a una contingencia extrema.

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/16920
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorValenzuela Santillán, Alex David-
dc.contributor.authorPelaes Ramírez, Rodrigo Xavier-
dc.date.accessioned2019-02-22T15:55:59Z-
dc.date.available2019-02-22T15:55:59Z-
dc.date.issued2019-02-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/16920-
dc.descriptionEste artículo propone la coordinación automática de protecciones de distancia en un sistema de transmisión, después de una contingencia extrema. El objetivo de la coordinación automática es reestablecer la sensibilidad, selectividad y confiabilidad de las protecciones de distancia. Primero se realiza la coordinación de protecciones de distancia en un sistema de transmisión en condiciones iniciales, después se plantea dos escenarios distintos en los cuales acontece una contingencia extrema, que ocasiona la indisponibilidad de varios elementos del sistema, debido a ello, las corrientes de cortocircuito del sistema varían y el sistema de transmisión adopta una nueva topología, por lo tanto se recalcula automáticamente el ajuste de las protecciones de distancia. Como resultado de la coordinación automática, las protecciones de distancia se encuentran listas para actuar en caso de existir una falla en el sistema de transmisión. Los algoritmos fueron desarrollados mediante los softwares MATLAB y PowerFactory, y se aplican a un sistema eléctrico de potencia de 39 barras propuesto por IEEE.spa
dc.description.abstractThis article proposes the automatic coordination of distance protection in a transmission system after an extreme contingency. The goal of an automatic coordination is to restore the sensitivity, selectivity and reliability of the distance protections. First a coordination of distance protections is made in a transmission system in initial conditions. Then two different scenarios are proposed, in the two scenarios there is an extreme contingency, the extreme contingency causes the unavailability of several elements of the system, due to the unavailability of elements of the system, the short-circuit currents change in the system and the transmission system adopts a new topology, therefore the adjustment of the distance protections is automatically recalculated. As a result of the automatic coordination, the distance protections are ready to act if there is a fault in the transmission system The algorithms were developed in MATLAB and PowerFactory softwares, and they are applied to an electric power system of 39 nodes proposed by the IEEE.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectAUTOMATIZACIÓNspa
dc.subjectTRANSMISIÓNspa
dc.subjectMÁQUINASspa
dc.subjectTOPOLOGÍAspa
dc.subjectCONTROL - SISTEMASspa
dc.titleCoordinación autimática de protecciones de distancia en líneas de transmisión frente a una contingencia extrema.spa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-ST003934.pdfTexto completo2,39 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons