Plan de manejo de los nivelos de iluminación del área administrativa de una empresa de servicios metrológicos de Guayaquil.

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/14844
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrdoñez Ramírez, Virgilio-
dc.contributor.authorVillegas Carrasco, Cristina Andrea-
dc.date.accessioned2017-11-10T19:31:15Z-
dc.date.available2017-11-10T19:31:15Z-
dc.date.issued2017-09-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/14844-
dc.descriptionEl presente estudio es de gran importancia, tanto para colaboradores como para la empresa en cuestión, teniendo en cuenta que se propone implementar mejoras en corto plazo, para cumplir con lo establecido en las normativas vigente y disminuir los efectos de la deficiente iluminación en la salud de los trabajadores. Para esto, fue necesario aplicar la observación participante y medir a través del luxómetro el nivel de iluminación por cada puesto de trabajo realizándose tres tomas diferentes de medidas (posiciones) con un intervalo de dos minutos cada uno. A partir de la aplicación del instrumento se pudo determinar el mal estado de las luminarias existentes en la empresa y además, la existencia de 5 posiciones que no cumplen el mínimo permisible de iluminación como son el caso del vendedor 1 en la posición de medida 2, el vendedor 2 en las posiciones 1 y 3, por último, el vendedor 4 en las posiciones 1 y 3. Para los departamentos donde se encuentran dichos vendedores se propone un plan que contribuirá a incrementar los niveles de iluminación en los puestos de trabajo.en_US
dc.description.abstractThe present research aims to elaborate a management plan to adjust the lighting levels of the administrative area of the Metrology Services Company of the city of Guayaquil, to the levels established in Decree 2393. For this, it was necessary apply the participant observation and measure through the luxometer the level of illumination for each work place being made three different shots (positions) of measures with an interval of two minutes each one.From the application of the instrument it was possible to determine the poor state of the existing luminaries in the company and also, the existence of 5 positions that do not meet the minimum permissible illumination as are the case of the seller 1 in the measurement position 2, the seller 2 in positions 1 and 3, finally, the seller 4 in positions 1 and 3. For the departments where these sellers are proposed a plan that will contribute to increase the levels of illumination of workstationsen_US
dc.language.isospaen_US
dc.rightsopenAccessen_US
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectNIVEL DE ILUMINACIÓNen_US
dc.subjectLUMINARIASen_US
dc.subjectSEGURIDAD INDUSTRIALen_US
dc.subjectLUXÓMETROen_US
dc.titlePlan de manejo de los nivelos de iluminación del área administrativa de una empresa de servicios metrológicos de Guayaquil.en_US
dc.typeArticleen_US
ups.carreraIngeniería Industrial-
ups.sedeSede Guayaquil-
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-GT002012.pdfTexto completo569,89 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons