Estudio de presencia de humedad en el aceite dieléctrico del autotransformador de potencia utilizado en transmisión para estimar la vida útil remanente

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/21903
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBucheli Ávila, Juan Alberto-
dc.contributor.authorGaleas Mendoza, Santiago Omar-
dc.date.accessioned2022-02-22T21:28:41Z-
dc.date.available2022-02-22T21:28:41Z-
dc.date.issued2022-02-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/21903-
dc.descriptionEl presente documento, se basa en el cálculo para estimar la vida útil remanente del autotransformador trifásico de potencia de la subestación Mulaló con una capacidad de 66,7 MVA, cuya relación de transformación es de 138 kV/ 69 kV /13.8 kV, cuya operación y mantenimiento está a cargo de la Corporación Eléctrica del Ecuador en su Unidad de Negocio Transelectric, mediante la gestión de la Zona Operativa Nororiental. Al autotransformador antes mencionado, se lo hace un estudio para determinar la vida remanente en años, específicamente desde la concentración de furanos analizados al aceite dieléctrico y mediante los resultados arrojados del laboratorio previo una muestra de aceite extraída del ATQ, en el cual se considerará los resultados y realizará un seguimiento y un análisis estadístico considerando para observar el comportamiento de la degradación del papel de autotransformador de la subestación Mulaló ya que está expuesto a las altas temperaturas y oxidación, ratificando que estos compuestos se determinan mediante pruebas de laboratorio. La predicción del tiempo de vida remanente del autotransformador, se asocia directamente con la condición del papel aislante, en conclusión, la vida del autotransformador depende de la vida del papel aislante. Según los resultados de laboratorio, realizado al autotransformador ATQ de la subestación Mulaló, se determinará que, a pesar de estar en operación muchos años, estos equipos pueden aún aumentar su vida útil, con un buen mantenimiento y condiciones de operación a temperaturas adecuadas.spa
dc.description.abstractThis document is based on the calculation to estimate the remaining useful life of the three-phase power autotransformer of the Mulaló substation with a capacity of 66.7 MVA, whose transformation ratio is 138 kV/ 69 kV /13.8 kV, whose operation and maintenance is in charge of the Corporación Eléctrica del Ecuador in its Transelectric Business Unit, through the management of the Northeastern Operative Zone. To the above mentioned autotransformer, a study is made to determine the remaining life in years, specifically from the concentration of furans analyzed to the dielectric oil and by means of the results thrown from the previous laboratory a sample of oil extracted from the ATQ, in which the results will be considered and a follow-up and statistical analysis will be made considering to observe the behavior of the degradation of the autotransformer paper of the Mulaló substation since it is exposed to the high temperatures and oxidation, ratifying that these compounds are determined by means of laboratory tests. The prediction of the remaining life time of the autotransformer is directly associated with the condition of the insulating paper, in conclusion, the life of the autotransformer depends on the life of the insulating paper. According to the laboratory results, carried out on the ATQ autotransformer of Mulaló substation, it will be determined that, despite being in operation for many years, this equipment can still increase its useful life, with good maintenance and operating conditions at adequate temperatures.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectPROPIEDADES DE LA MATERIAspa
dc.subjectVISCOSIDADspa
dc.subjectACEITES MINERALESspa
dc.subjectACEITES AISLANTESspa
dc.subjectTRANSFORMADORES ELÉCTRICOSspa
dc.titleEstudio de presencia de humedad en el aceite dieléctrico del autotransformador de potencia utilizado en transmisión para estimar la vida útil remanentespa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa