Análisis geotécnico de la cimentación del bloque “G” de la Universidad Politécnica Salesiana Sede Quito, Campus Sur, empleando el software midas GTS NX

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/20493
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRodríguez Badillo, Freddy Israel-
dc.contributor.authorRosero Narváez, Jorge Andrés-
dc.date.accessioned2021-07-20T17:45:27Z-
dc.date.available2021-07-20T17:45:27Z-
dc.date.issued2021-07-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/20493-
dc.descriptionHa surgido cierta inquietud por la funcionalidad del Bloque G de la Universidad Politécnica Salesiana sede Quito Campus Sur, ya que se han presentado ciertas fisuras en esta estructura, probablemente por asentamientos excesivos o asentamientos diferenciales, por esta razón se realiza el análisis a partir de datos proporcionados por el Laboratorio de Suelos de la Universidad para cotejar la información y corroborar con modelos de elementos finitos generados con la ayuda del software MIDAS GTS NX, en el cual se generan situaciones geotécnicas que experimenta el edificio. Simulando varios escenarios en diferentes modelos, obteniendo resultados que permitieron comprender la interacción del suelo y la estructura. Los asentamientos diferenciales experimentados por la edificación no conllevan a una problemática, están en rango admisibles propuestos por las normas vigentes.spa
dc.description.abstractHas emerged a concern by the functionality of the Block G of the Universidad Politecnica Salesiana sede Quito South Campus, as they have been presented some cracks in this structure, probably due to settlements excessive or settlements differential, for this reason, the analysis is carried out on the basis of data provided by the Laboratory of Soils from the University to collate the information and corroborate with finite element models generated with the help of the software, MIDAS GTS NX, which generate situations geotechnical experiencing the building. Simulating several scenarios in different models, obtaining results that allowed understanding the interaction of soil and structure. The differential settlements experienced by the building do not lead to a problem, they are in admissible range proposed by the current regulations.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA CIVILspa
dc.subjectANÁLISIS ESTRUCTURALspa
dc.subjectCIMIENTOSspa
dc.subjectUNIVERSIDADESspa
dc.subjectSOFTWARE DE APLICACIÓNspa
dc.titleAnálisis geotécnico de la cimentación del bloque “G” de la Universidad Politécnica Salesiana Sede Quito, Campus Sur, empleando el software midas GTS NXspa
dc.typebachelorThesisspa
ups.carreraIngeniería Civilspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS384.pdfTexto completo8,53 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons