Comportamiento experimental de conexiones soldadas entre tubos cuadrados de acero conformados por perfiles G de 60X30X10X2 y 80X40X15X3 mm sometidas a carga monotónica

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18756
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRomero Romero, Carlos Alberto-
dc.contributor.authorBejarano Saritama, Julio Sebastián-
dc.contributor.authorVerdugo Astudillo, Franklin Paul-
dc.date.accessioned2020-07-06T19:28:58Z-
dc.date.available2020-07-06T19:28:58Z-
dc.date.issued2020-07-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18756-
dc.descriptionEsta investigación tuvo por objetivo analizar mediante la realización de seis ensayos el comportamiento elastoplástico de conexiones soldadas con tubos de acero de sección cuadrada conformada por perfiles G de 60x30x2 y 80x40x3mm, sometidas a carga monotónica mediante el análisis experimental de la distorsión de la geometría de la sección transversal de los elementos de la unión vigacolumna. Para esto fue necesario diseñar y fabricar un marco soporte con un sistema de aplicación de carga en la maquina universal del laboratorio de mecánica de materiales de la Universidad Politécnica Salesiana (UPS). Cada prueba consistió en imponer una carga progresiva en la conexión superior del pórtico, para medir los desplazamientos y distorsión de la geometría de los elementos unión viga - columna de la conexión inferior. Los resultados evidenciaron que la conexión sin refuerzo presenta una falla local generada por fuerza axial excesivamente concentrada (punzonado) que transmite la viga a la columna, que induce disminución de la carga de colapso experimental del pórtico en aproximadamente 12.82% con respecto a la teórica. Además, distorsiona la sección transversal de la columna en la unión soldada y da formación a la rótula plástica en dicho elemento por fuerza axial concentrada (punzonado) en la columna y distorsiona la sección de la viga dando formación de la rótula plástica en el elemento en cuestión.spa
dc.description.abstractThe objective of this research was to analyze, through six tests, the elastoplastic behavior of welded connections with square-shaped steel tubes made up of 60x30x2 and 80x40x3mm G profiles, subjected to monotonic loading by experimental analysis of the distortion of the cross-section geometry of the beam-column joint elements. It was necessary to design and manufacture a support frame with a universal machine load application system in the materials mechanics laboratory of the Salesian Polytechnic University (UPS). Each test consisted of imposing progressive loading on the upper connection of the gantry, to measure in displacements and distortion of the geometry of the connecting elements column beam of the lower connection. The results showed that the connection without reinforcement presents a local fault generated by excessively concentrated axial force (punching) that transmits the beam to the column, which induces a decrease in the experimental collapse load of the gantry by approximately 12.82% with respect to the theory. In addition, it distorts the cross-section of the column in the welded joint and the formation of the plastic kneecap in said element. The plates (stirrups) installed in the column of the welded joint avoids the failure by concentrated axial force (punching) in the column and distorts the beam section by forming the plastic ball joint in the element in question.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectIINGENIERÍA CIVILspa
dc.subjectANÁLISIS DE MATERIALESspa
dc.subjectSOLDADURAspa
dc.subjectACEROspa
dc.titleComportamiento experimental de conexiones soldadas entre tubos cuadrados de acero conformados por perfiles G de 60X30X10X2 y 80X40X15X3 mm sometidas a carga monotónicaspa