Monitoreo y evaluación del impacto ambiental del material particulado PM10 y PM2,5 en la Universidad Politécnica Salesiana campus sur.

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/17086
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorUlloa Vaca, Carlos Andrés-
dc.contributor.authorRubio Bautista, Jonathan Rafael-
dc.date.accessioned2019-03-18T14:22:27Z-
dc.date.available2019-03-18T14:22:27Z-
dc.date.issued2019-03-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/17086-
dc.descriptionLa presente investigación monitoreó y evaluó los contaminantes presentes en la atmósfera que alteran la calidad del aire ambiente, en cuanto a lo que tiene que ver con el material particulado gravimétrico en las inmediaciones de la Universidad Politécnica Salesiana “Campus Sur”. Con la finalidad de proporcionar información que permita tomar medidas de prevención de enfermedades respiratorias. Para la evaluación de los contaminantes atmosféricos se empleó la ayuda de un muestreador de material particulado de alto volumen Hi-Vol para PM10 y otro para PM 2.5. Los mismos que nos permitieron determinar la concentración de cada uno de los contaminantes. Se empleó el método gravimétrico (CFR) “Code of Federal Regulation, respaldado por el Acuerdo Ministerial 097A Anexo 4 y al Servicio de Acreditación Ecuatoriano (SAE). Estos contaminantes se modelaron con el programa ArcMap 10.5 donde se ve las áreas más contaminadas en los alrededores de la zona de estudio, obteniendo como resultado que en los 5 puntos de monitoreo se cumple con los límites máximos permisibles estipulados en la norma de Calidad del Aire Ambiente o Nivel de inmisión, Anexo 4, A.M. 097A y al A.M.0.61 que sustituye al LIBRO VI, TULSMA. Los mismos que a su vez fueron relacionados con la cantidad de vehículos livianos y pesados que circulaban en las inmediaciones de la Universidad Politécnica Salesiana “Campus Sur”, revelando su influencia directa con los resultados obtenidos del monitoreo.spa
dc.description.abstractThis research evaluated and monitored contaminants in the atmosphere that affect the quality of ambient air, as to what that has to do with the gravimetric particulate matter in the vicinity of the Polytechnic Salesian University "Campus Sur". In order to provide information to make prevention of respiratory diseases. For the evaluation of air pollutants using a particulate sampler high Hi-Vol Volume PM10 PM and another for 2.5 was used. They enabled us to determine the concentration of each pollutant. the gravimetric method (CFR) "Code of Federal Regulation, backed by AM 097a Annex 4 and the Ecuadorian Accreditation Service (SAE) was used. These pollutants were modeled with ArcMap 10.5 program where you see the most polluted areas around the study area, resulting in the 5 points of monitoring compliance with the maximum permissible limits stipulated in the standard Air Quality environment or immission level, Annex 4, AM 097a and AM0.61 replacing BOOK VI, TULSMA. They in turn were related to the amount of light and heavy vehicles circulating in the vicinity of the Salesian University "Campus Sur", revealing its direct influence on the results of monitoring.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA AMBIENTALspa
dc.subjectATMÓSFERAspa
dc.subjectCONTAMINACIÓNspa
dc.subjectAIREspa
dc.subjectAPARATO RESPIRATORIO - ENFERMEDADESspa
dc.titleMonitoreo y evaluación del impacto ambiental del material particulado PM10 y PM2,5 en la Universidad Politécnica Salesiana campus sur.spa
dc.typebachelorThesisspa
ups.carreraIngeniería Ambientalspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-ST004034.pdfTexto completo3,64 MBAdobe PDFVisualizar/Abrir