Análisis del comportamiento de los componentes de torres de trasmisión eléctrica frente a sobretensiones transitorias producidas por descargas atmosféricas

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/20719
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCarrión Galarza, Diego Francisco-
dc.contributor.authorPrado Santamaria, Henri Bladimir-
dc.date.accessioned2021-08-14T03:02:45Z-
dc.date.available2021-08-14T03:02:45Z-
dc.date.issued2021-08-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/20719-
dc.descriptionLas líneas de transmisión son una parte fundamental y físicamente la parte más extensa del sistema eléctrico de potencia. Es de suma importancia mantener la confiabilidad en las líneas independientemente de las condiciones ambientales del sector por el cual atraviesan las mismas. El estudio de la coordinación del aislamiento y el análisis de los transitorios ocasionados por las descargas atmosféricas en líneas de trasmisión, son de mucha importancia para el correcto funcionamiento del sistema, para de esa manera cumplir con los requerimientos de la demanda. Para el estudio del comportamiento que tienen los elementos que conforman las líneas de transmisión frente a descargas atmosféricas, se realizó el modelamiento de torres de trasmisión de 138, 230 y 500 kV en base a la representación de sus estructuras por medio de impedancias de cono y cilindro. Para este estudio se realizó el modelamiento de una descarga atmosférica cuando esta impacta directamente en el cable de guarda. Finalmente se realizó el análisis de las sobretensiones y las formas de onda de corriente reflejadas en cada uno de los elementos verificando que pare este caso de estudio no existen fallas en el aislamiento de las torres de transmisión.spa
dc.description.abstractTransmission lines are a fundamental part and physically the most extensive part of the electrical power system. It is very important to maintain the reliability of the lines regardless of the environmental conditions of the sector which they pass. The study of the coordination of the isolation and the analysis of the transients caused by the atmospheric lightning in transmission lines are of most important for the correct operation of the system in order to comply with the demand requirements. For the study of the behavior of the elements that make up the transmission lines against atmospheric lightning, the transmission towers of 138, 230 and 500 kV were modeled based on the representation of their structures by means of cone and cylinder impedances. For this study, the modeling of an atmospheric lightning was carried out when it impacts directly on the guard wire. Finally, the analysis of the overvoltage and the current waveforms reflected in each of the elements was carried out, verifying that for this case study there are no faults in the insulation of the transmission towers.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectAISLAMIENTOspa
dc.subjectDESCARGA ATMOSFÉRICAspa
dc.titleAnálisis del comportamiento de los componentes de torres de trasmisión eléctrica frente a sobretensiones transitorias producidas por descargas atmosféricasspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa