Análisis dinámico de la estabilidad transitoria en los sistemas de potencia posterior a la conmutación óptima de líneas de transmisión

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/27465
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCarrión Galarza, Diego Francisco-
dc.contributor.authorPineda Guaman, Joel Alfonso-
dc.date.accessioned2024-03-26T21:30:27Z-
dc.date.available2024-03-26T21:30:27Z-
dc.date.issued2024-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/27465-
dc.descriptionEl presente articulo científico tuvo como objetivo analizar la estabilidad transitoria posterior a la conmutación óptima de líneas de transmisión (OTS), la cual se acoge a los flujos óptimos de potencia DC, dando lugar al DCOTS, que facilita la conmutación óptima de las líneas de transición sin afectar a la carga, considerando tanto el despacho óptimo de energía cumpliendo con las limitaciones técnicas y operativas establecidas por el sistema. Esto se realizó para tres distintos escenarios, cuando existe una, dos y tres líneas de transmisión conmutadas. Todo esto fue un caso de optimización resuelto mediante programación lineal entera mixta (MILP). Por medio del software de optimización GAMS y MATLAB para la modelación y tratamiento de los datos. Se trabajó sobre los modelos estándar de 14 y 30 barras del IEEE de los cuales se pudo apreciar el análisis de la estabilidad transitoria en las barras de generación ante escenarios adversos. Además, el uso de la programación dinámica permitió obtener resultados precisos de manera rápida, aprovechando las ventajas computacionales disponibles.spa
dc.description.abstractThe objective of this scientific article was to analyze the transient stability after optimal switching of transmission lines (OTS), which adheres to optimal DC power flows, resulting in DCOTS, which facilitates optimal switching of transition lines without affecting the load. Optimal energy dispatch was considered, complying with the technical and operational limitations established by the system. This analysis was carried out for three different scenarios, when there are one, two, and three switched transmission lines. All of this was an optimization case solved by mixed integer linear programming (MILP). GAMS and MATLAB optimization software were used for data modeling and processing. The standard 14 and 30 bar models of the IEEE were worked on, in which the transient stability analysis in the generation bars could be appreciated under adverse scenarios. In addition, the use of dynamic programming allowed for fast and accurate results, taking advantage of available computational advantages.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectSISTEMA DE ENERGÍA ELÉCTRICAspa
dc.subjectCONTROL ENERGÉTICOspa
dc.subjectCONMUTACIÓN ÓPTIMAspa
dc.titleAnálisis dinámico de la estabilidad transitoria en los sistemas de potencia posterior a la conmutación óptima de líneas de transmisiónspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TTS1834.pdfTexto completo1,68 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons