Estrategia de respuesta de demanda de emergencia basado en el óptimo despacho de energía de una micro-red tipo hospitalaria

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/23301
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGarcía Torres, Edwin Marcelo-
dc.contributor.authorSandoval Rosales, Hugo Ricardo-
dc.date.accessioned2022-09-12T20:48:26Z-
dc.date.available2022-09-12T20:48:26Z-
dc.date.issued2022-09-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/23301-
dc.descriptionEste documento centra su investigación en el óptimo despacho energético para una carga de tipo preferencial como lo es un hospital, manteniendo un alto consumo energético durante las 24 horas del día. Para ello la demanda ha sido abastecida de manera que funcione como una red aislada utilizando una red fotovoltaica, grupo electrógeno y un banco de baterías. Además, se estableció la manera óptima de abastecer la demanda crítica modelando el comportamiento más parecido de la carga para estudiar a detalle la micro-red durante un caso de contingencia donde la carga sea privada de la red eléctrica local. Por lo tanto, se estableció que debido a la poca eficiencia que brinda las baterías y los paneles solares para abastecer una carga crítica, la mejor manera de despacho es utilizar los paneles solares para como fuentes de calefacción y calentadores de agua que representan menos del 8% del consumo total de la potencia, también se considera necesario el grupo electrógeno para satisfacer la fiabilidad del sistema, ya que es fundamental estar preparados ante una contingencia.spa
dc.description.abstractThis document focuses its research on the optimal energy dispatch for a preferential load such as a hospital, maintaining high energy consumption 24 hours a day. For this, the demand has been supplied in such a way that it works as an isolated network using a photovoltaic network, a generator set and a battery bank. In addition, the optimal way to supply the critical demand is established, modeling the most similar behavior of the load to study the micro-grid in detail during a contingency case where the load is deprived of the local electrical network. Therefore, it was ensured that due to the low efficiency that batteries and solar panels provide to supply a critical load, the best way to dispatch is to use solar panels for heating sources and water heaters that represent less than 8 % of the total power consumption, the generator set is also considered necessary to satisfy the reliability of the system, since it is essential to be prepared for a contingency.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectPLANIFICACIÓN ESTRATÉGICAspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICA - CONTROLspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.titleEstrategia de respuesta de demanda de emergencia basado en el óptimo despacho de energía de una micro-red tipo hospitalariaspa