Análisis del efecto del SAR provocado por una antena microstrip en onda milimétrica

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/22975
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorArguero Tello, Johanna Berenice-
dc.contributor.authorLlumiquinga Bungacho, Jhonny Xavier-
dc.contributor.authorOlmedo Garcés, Fredy Alexander-
dc.date.accessioned2022-07-29T21:54:31Z-
dc.date.available2022-07-29T21:54:31Z-
dc.date.issued2022-07-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/22975-
dc.descriptionSe analizó el efecto de la Tasa de Absorción específica (SAR -Rate Absorption Specific) de una antena microstrip en la banda de onda milimétrica mediante el software ANSYS HFSS. Se realizó el diseño de la antena microstrip en la banda de 3 GHz, para posterior evaluar el SAR en la configuración mano-cabeza (fantoma) producido por las terminales móviles de 5G. Tanto para la configuración mano/cabeza, se trabajó con una potencia de 35 mW, para la simulación del fantoma se obtuvo como resultados un valor de SAR de 1.8205 W/Kg para la banda de 3.4 GHz, en la banda de 3.5 GHz un SAR de 2.6682 W/Kg y para 3.6 GHz se obtuvo 3.8367 W/Kg. Mientras que la configuración mano en la banda de 3.4 GHz se consiguió un valor de SAR de 2.3039 W/Kg, para 3.5 GHz 3.8481 W/Kg y finalmente para 3.6 GHz un valor de 3.9600 W/kg, esto demuestra que los diseños no son nocivos para la salud ya que están dentro del rango la normativa por ICNIRP (Comisión Internacional para la Protección contra las Radiaciones No Ionizantes).spa
dc.description.abstractThe effect of the Specific Absorption Rate (SAR) of a microstrip antenna in the millimeter wave band was analyzed using the ANSYS HFSS software. The design of the microstrip antenna in the 3 GHz band was carried out, to later evaluate the SAR in the hand head configuration (phantom) produced by 5 G mobile terminals. Both for the hand/head configuration, we worked with a power of 35 mW, for the simulation of the phantom, a SAR value of 1.8205 W/Kg for the 3.4 GHz band was obtained as a result, in the 3.5 GHz band a SAR of 2.6682 W/Kg and for 3.6 GHz 3.8367 W/Kg was obtained. While the handheld configuration in the 3.4 GHz band achieved a SAR value of 2.3039 W/Kg, for 3.5 GHz 3.8481 W/Kg and finally for 3.6 GHz a value of 3.9600 W/kg, this shows that the designs are not harmful to health since they are within the range of regulations by ICNIRP (International Commission for Protection against Non-Ionizing Radiation).spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELECTRÓNICAspa
dc.subjectANÁLISIS DE SISTEMASspa
dc.subjectTASA DE ABSORCIÓN ESPECÍFICAspa
dc.subjectANTENAS (ELECTRÓNICA)spa
dc.subjectTELECOMUNICACIONESspa
dc.subjectONDAS ELECTROMAGNÉTICASspa
dc.titleAnálisis del efecto del SAR provocado por una antena microstrip en onda milimétricaspa
dc.typebachelorThesisspa
ups.carreraIngeniería Electrónicaspa
ups.sedeSede Quitospa