Filtrado de armónicos en un sistema de distribución con cargas no lineales para el control de la distorsión armónica

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/22554
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCuji Cuji, Cristian Cristóbal-
dc.contributor.authorPaladines Guacho, Cristian David-
dc.date.accessioned2022-05-12T22:54:18Z-
dc.date.available2022-05-12T22:54:18Z-
dc.date.issued2022-05-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/22554-
dc.descriptionEl artículo presenta resultados del porcentaje de THD y corrección de los mismos mediante el análisis y simulación de filtrado hibrido en un sistema eléctrico de potencia de 37 barras IEE, en el cual se estudiará varios escenarios los cuales son: sistema sin perturbación, con perturbación, con filtro activo, filtro pasivo y filtro hibrido. Conociendo las causas, comportamiento y lo que ocasiona conectar cargas no lineales. Las cargas no lineales generan una serie de afectaciones entre ellas está el tipo de armónico, variación del factor de potencia y resonancia las cuales hacen que el sistema sea inestable y trabaje de forma inadecuada. Lo que se propone es manejar el programa Matlab con un script el cual contenga los parámetros del sistema de barras que conjuntamente a Simulink se realizará la simulación del sistema que contiene algunos componentes como cargas, barras, inversor y lo más importante que es la combinación de un filtro activo y un pasivo que se denomina filtros híbridos; los cuales aportarán a reducir el porcentaje de THD, mostrando los cinco escenarios analizados mediante gráficas de forma de onda en cada una de ellas; para el voltaje, corriente y el tiempo de estabilización del mismo.spa
dc.description.abstractThe article presents results of the percentage of THD and their correction through the analysis and simulation of hybrid filtering in an electrical power system of 37 bars IEE, in which several scenarios will be studied, which are: system without disturbance, with disturbance, with active filter, passive filter and hybrid filter. Knowing the causes, behavior and what causes connecting non-linear loads. Non-linear loads generate a series of affectations among them is the type of harmonic, variation of the power factor and resonance which make the system unstable and work inadequately. What is proposed is to manage the Matlab program with a script which has the parameters of the bar system that, together with Simulink, simulates the system that contains some components such as loads, bars, inverter and the most important thing, which is the combination of an active and a passive filter which are called hybrid filters; which will contribute to reduce the percentage of THD, showing the five scenarios analyzed by means of waveform graphs in each one of them; for the voltage, current and connection time of the same.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectELECTRICIDADspa
dc.subjectANÁLISIS DE REDES ELÉCTRICASspa
dc.subjectENERGÍA ELÉCTRICAspa
dc.subjectRECTIFICADORES DE CORRIENTE ELÉCTRICAspa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICA - CONTROLspa
dc.titleFiltrado de armónicos en un sistema de distribución con cargas no lineales para el control de la distorsión armónicaspa
dc.typebachelorThesisspa
ups.carreraElectricidadspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado