Sistema de medición del tamaño de la pupila con visión artificial para investigación en psicología e inteligencia artificial del Grupo IDEIAGEOCA.

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/22224
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorOrtega Martínez, Holger Raúl-
dc.contributor.authorChango Montaluisa, Evelyn Carolina-
dc.contributor.authorSinchiguano Guananga, Bryan David-
dc.date.accessioned2022-03-18T22:29:12Z-
dc.date.available2022-03-18T22:29:12Z-
dc.date.issued2022-03-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/22224-
dc.descriptionEl presente trabajo tiene como objetivo desarrollar un sistema de medición del tamaño de la pupila con visión artificial, para investigación en psicología del Grupo IDEIAGEOCA. El sistema consta de dos etapas que son: preprocesamiento de imágenes y segmentación; en la primera etapa utiliza obtención de imágenes, redimensionamiento de imágenes y en la segunda utiliza detección de iris, detección de pupila y medición del diámetro de la pupila. Las imágenes de ojos utilizadas para la experimentación se tomaron de dos fuentes, de una cámara y del Internet. Como resultado de unificar los módulos del sistema de visión por computador (svc), se obtuvo un 80\% de fiabilidad al medir el tamaño de la pupila. Para la evaluación del sistema se utilizó dos métricas, la precisión y el error entre la medida real y la medida automática de la pupila, por lo tanto, el sistema está optimizado manteniendo un nivel aceptable de eficiencia.spa
dc.description.abstractThe objective of this work is to develop a system for measuring pupil size with artificial vision, for research in psychology of the IDEIAGEOCA Group. The system consists of two stages: image preprocessing and segmentation; in the first stage it uses image acquisition, image resizing and in the second stage it uses iris detection, pupil detection and pupil diameter measurement. The eye images used for experimentation were taken from two sources, from a camera and from the Internet. As a result of unifying the modules of the computer vision system (svc), 80 % reliability was obtained when measuring pupil size. Two metrics were used to evaluate the system, the accuracy and the error between the actual measurement and the automatic pupil measurement, therefore, the system is optimized while maintaining an acceptable level of efficiency.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectCOMPUTACIÓNspa
dc.subjectANÁLISIS DE SISTEMASspa
dc.subjectPROGRAMAS PARA COMPUTADORspa
dc.subjectPUPILOMETRÍAspa
dc.subjectMEDICIÓNspa
dc.subjectPUPILA (OJOS)spa
dc.subjectVISIÓN ARTIFICIALspa
dc.subjectPSICOLOGÍAspa
dc.subjectINTELIGENCIA ARTIFICIALspa
dc.titleSistema de medición del tamaño de la pupila con visión artificial para investigación en psicología e inteligencia artificial del Grupo IDEIAGEOCA.spa
dc.typebachelorThesisspa
ups.carreraComputaciónspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS704.pdfTexto completo7,71 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons