Compensación reactiva en un sistema eléctrico de potencia de 9 barras IEEE con cargas no lineales mediante un Dstatcom utilizando el método PQ y modulación por histéresis para su control

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/21251
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorEndara Vélez, Iván David-
dc.contributor.authorArreaga Carpio, Jhon Henry-
dc.date.accessioned2021-10-29T22:42:26Z-
dc.date.available2021-10-29T22:42:26Z-
dc.date.issued2021-
dc.identifier.urihttp://dspace.ups.edu.ec/handle/123456789/21251-
dc.descriptionSe utiliza la herramienta de Simulink del software Matlab para simular el sistema de 9 barras de la IEEE a nivel de 13.8KV sustituyendo las cargas lineales de las barras 5 y 6 por otras no lineales para que se generen armónicos en la red, lo cual produce una distorsión en las ondas de corrientes, por lo que para disminuir esta distorsión de onda se agregará al sistema un compensador de reactivos llamado DSTATCOM, el cual será dimensionado previamente para satisfacer la demanda reactiva total que producen estas corrientes armónicas. El DSTATCOM será controlado por los disparos de los IGBT’s mediante un control por banda de histéresis que utilizará la teoría de las potencias instantáneas PQ para poder separar la potencia reactiva que es generada por los armónicos de la que se genera por las impedancias de las líneas, transformadores y demás elementos comunes que comprenden un sistema de potencia.spa
dc.description.abstractThe Simulink tool of the Matlab software is used to simulate the IEEE 9 bus system at a 13.8 KV level, replacing the linear loads of busbars 5 and 6 with non-linear ones so that harmonics are generated in the network, which produces a distortion in the current waves, so to reduce this wave distortion, a reactive compensator called DSTATCOM will be added to the system, which will be previously dimensioned to satisfy the total reactive demand produced by these harmonic currents. The DSTATCOM will be controlled by the IGBT's triggers through a hysteresis band control that will use the PQ instantaneous power theory to be able to separate the reactive power that is generated by the harmonics from that generated by the impedances of the lines, transformers and other common elements that comprise a power system.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectCONTROLspa
dc.subjectDSTATCOMspa
dc.subjectSISTEMA DE DISTRIBUTIONspa
dc.subjectSIMULACIÓN MATLAB SIMULINKspa
dc.subjectSIMSPOWERSYSTEMspa
dc.subjectARMÓNICOSspa
dc.titleCompensación reactiva en un sistema eléctrico de potencia de 9 barras IEEE con cargas no lineales mediante un Dstatcom utilizando el método PQ y modulación por histéresis para su controlspa
dc.typemasterThesisspa
ups.carreraMaestría en Electricidadspa
ups.sedeSede Guayaquilspa
Pertenece a las colecciones: Posgrado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS-GT003463.pdfTexto completo1,44 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons