“Análisis de cargabilidad de redes eléctricas de distribución basado en la modificación del algoritmo de Gauss-Seidel”

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19417
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCarrión Galarza, Diego Francisco-
dc.contributor.authorGancino Bustillos, Henry Saúl-
dc.date.accessioned2020-11-11T04:13:19Z-
dc.date.available2020-11-11T04:13:19Z-
dc.date.issued2020-11-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/19417-
dc.descriptionEn los sistemas alimentadores, una de las funciones principales es la distribución de energía, misma que se distribuye a través de conductores eléctricos con una topología radial. El mal funcionamiento de estos sistemas se produce por diferentes razones, una de las principales ocurre cuando la corriente supera el factor de sobrecarga en la línea, creando que el conductor supere su límite térmico, sin embargo, esto se puede evitar analizando el flujo de potencia de los sistemas de distribución, para que existan resultados confiables en sistemas radiales y de esta manera determinar el punto de corriente crítico en el conductor antes de que ocurra una extensión térmica. Por lo mencionado, el siguiente articulo tiene como finalidad la adaptación del algoritmo de Gauss-Seidel en sistemas de distribución, y determinar un punto crítico de corriente en los conductores de los sistemas alimentadores de 13 y 34 nodos del IEEE. A través de los resultados obtenidos se podrá definir a que nivel de corriente empieza a existir una extensión térmica en los conductores y se verificarán los resultados del flujo de potencia con un simulador el cual afirmará los resultados obtenidos.spa
dc.description.abstractIn the feeder systems, the main function is the distribution of energy, that is distribute through the electric conductors with a radial topology. The bad operation of this systems is produced by several reason, the principal reason occur when the current surpasses the overload factor in the line, resulting in the conductor surpasses its thermal limit, but this can be avoided by analysing the potency flow of the distribution systems, so that exist reliable results in radial systems and of this form establish the critical current point in the conductor before thermal expansion occur. For the mentioned, the purpose of this article is to adapt of the algorithm of Gauss-Seidel in distribution systems, and to decide a current critical point in the conductors of the 13 and 34 nodes feeder systems of the IEEE. Through the results obtained, it will be may to define at which current level a thermal extension begins to exist in the conductors and the results of the potency flow will be verified with a simulator which will affirm the results obtained.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectPOTENCIA REACTIVA (INGENIERÍA ELÉCTRICA)spa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICAspa
dc.subjectREDES ELÉCTRICASspa
dc.title“Análisis de cargabilidad de redes eléctricas de distribución basado en la modificación del algoritmo de Gauss-Seidel”spa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado