Corrección del factor de potencia en micro-redes eléctricas ante el peligro de resonancia por alta penetración de cargas no lineales

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19390
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorÁguila Téllez, Alexander-
dc.contributor.authorRosero Rosero, Edison Alexander-
dc.date.accessioned2020-10-29T02:05:17Z-
dc.date.available2020-10-29T02:05:17Z-
dc.date.issued2020-10-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/19390-
dc.descriptionEl presente trabajo permite analizar la afectación técnica en el sistema eléctrico por la incorporación de dispositivos electrónicos de potencia, dado que dichos elementos introducen armónicos a los sistemas eléctricos, cuyas inclusiones causan efectos adversos tanto a la operatividad del sistema eléctrico como a sus elementos. Para el efecto se ha utilizado la implementación de motores DC como cargas en un sistema eléctrico modelo de 14 barras, el cual sirve para el análisis de los porcentajes de armónicos introducidos y su evaluación con los límites permitidos por la normativa estándar IEEE 519 sobre armónicos. Dicho análisis proporciona información necesaria en el diseño de filtros pasivos para la mitigación de contenido armónico en el sistema, constituidos por reactancias inductivas y capacitivas sintonizadas para eliminar las frecuencias armónicas distintas a la fundamental. Finalmente, el análisis se complementa con aspectos relacionados con la corrección del factor de potencia, ante el peligro de resonancia por la penetración de cargas no lineales y de esta forma evitar problemas de carácter técnico asociado al sobrecalentamiento de los elementos, para el efecto de realizar el estudio se usa los simuladores ATP y Power Factory - DigSilent.spa
dc.description.abstractThe present study allows us to analyze the technical impact on the electrical system due to the incorporation of power electronic devices, given that these elements introduce harmonics to electrical systems, the inclusions cause adverse effects both to the operation of the electrical system and to its elements. For this purpose, the implementation of DC motors has been used as loads in a 14-bar model electrical system, which is used for the analysis of the introduced harmonic percentages and their evaluation with the limits allowed by the IEEE 519 standard regulation on harmonics. Said analysis provides information necessary in the design of passive filters for the mitigation of harmonic content in the system, made up of inductive and capacitive reactances tuned to eliminate harmonic frequencies other than the fundamental one. Finally, the analysis is complemented with aspects related to the correction of the power factor, in view of the danger of resonance due to the penetration of nonlinear loads and thus avoid technical problems associated with the overheating of the elements, for the purpose of performing the study uses ATP and Power Factory simulators – DigSilent.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectELECTRÓNICA DE POTENCIAspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.titleCorrección del factor de potencia en micro-redes eléctricas ante el peligro de resonancia por alta penetración de cargas no linealesspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado