Óptima gestión de la producción energética entre sistemas fotovoltaicos de alta eficiencia y micro-generación eólica basado en lógica difusa

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19363
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCuji Cuji, Cristian Cristóbal-
dc.contributor.authorMediavilla Yandún, Ernesto Andrés-
dc.date.accessioned2020-10-20T21:17:14Z-
dc.date.available2020-10-20T21:17:14Z-
dc.date.issued2020-10-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/19363-
dc.descriptionEn este artículo se exhibe una central de energía renovable no convencional (ERNC) de tecnología mixta. Para su implementación se ha planteado como caso de estudio la factibilidad de suplantar la central termoeléctrica Dayuma (2MW), ubicada en la provincia de Orellana, Ecuador. Inicialmente se evaluó los recursos naturales energéticos de la zona, tales como, temperatura, irradiancia, velocidad de viento en sus puntos máximos, mínimos y promedio, en un intervalo de tiempo de cinco años. Posteriormente se utilizó controladores basados en lógica difusa, para el seguimiento del punto de máxima potencia (MPPT). Para el óptimo despacho de la energía producida, se utilizó un optimizador basado en programación lineal para encontrar el menor costo de producción. Finalmente se realizó un análisis de impacto medio ambiental relacionado con la emisión y absorción de CO2 en el área. En esta investigación se busca estimar la máxima generación posible mediante MPPT basado en un control lógico difuso y con esto definir la posibilidad de suplantar la central térmica ya mencionada.spa
dc.description.abstractThis article shows a mixed technology non-conventional renewable energy plant (NCRE). For its implementation, the feasibility of supplanting the Dayuma thermoelectric plant (2MW), located in the province of Orellana, Ecuador, has been proposed as a case study. Initially, the natural energy resources of the area were evaluated, such as temperature, irradiance, wind speed at its maximum, minimum and average points, in a time interval of five years. Later, controllers based on fuzzy logic were used to monitor the maximum power point (MPPT). For the optimal dispatch of the energy produced, an optimizer based on linear programming was used to find the lowest production cost. Finally, an environmental impact analysis was carried out related to the emission and absorption of CO2 in the area. This research seeks to estimate the maximum possible generation through MPPT based on a fuzzy logic control and with this define the possibility of supplanting the aforementioned thermal power plant.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectSISTEMAS DE ENERGÍA ELÉCTRICAspa
dc.subjectPRODUCCIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectENERGÍA SOLARspa
dc.subjectLÓGICA DIFUSAspa
dc.titleÓptima gestión de la producción energética entre sistemas fotovoltaicos de alta eficiencia y micro-generación eólica basado en lógica difusaspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS197.pdfTexto completo1,74 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons