Compensación VOLT-VAR mediante despacho óptimo de generación en microrredes eléctricas con alta penetración de generación distribuida

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/19269
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorÁguila Téllez, Alexander-
dc.contributor.authorQuilumbaquin Orbe, Miguel Ángel-
dc.date.accessioned2020-09-23T18:06:32Z-
dc.date.available2020-09-23T18:06:32Z-
dc.date.issued2020-09-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/19269-
dc.descriptionEn el presente trabajo se desarrolló un modelo de compensación de potencia activa y reactiva, en una microrred eléctrica a la que se implementó un flujo óptimo de potencia, para un análisis preciso del flujo que circula por la microrred, favoreciendo la integración de fuentes de generación de origen renovable. El método propuesto es por programación lineal entera mixta (MILP), al que se incorporó generación distribuida (GD) en una o varias barras establecidas. El algoritmo calcula una solución óptima, que satisface los requerimientos necesarios para garantizar fiabilidad y calidad en la microrred; desarrollado en la herramienta GAMS minimizando costos operativos en el sistema como función objetivo. Como análisis final se realizó una comparación de datos del sistema sin GD y con GD destacando una mejoría de los perfiles de voltaje, reducción de las pérdidas de potencia activa en las líneas, una mejora en el factor de potencia y comportamiento angular; que cumple con las restricciones planteadas a un mínimo costo de operación. Para el modelamiento del problema se utilizó el sistema de 9 barras de la IEEE.spa
dc.description.abstractIn the present work, an active and reactive power compensation model was developed, in an electric microgrid to which an optimal power flow was implemented, for a precise analysis of the flow circulating through the microgrid, favoring the integration of generation sources of renewable origin. The proposed method is by mixed integer linear programming (MILP), to which distributed generation (GD) was incorporated in one or more established bars. The algorithm calculates an optimal solution, which satisfies the necessary requirements to guarantee reliability and quality in the microgrid; developed in the GAMS tool minimizing operating costs in the system as an objective function. As a final analysis, a comparison of data from the system without GD and with GD was carried out, highlighting an improvement in the voltage profiles, reduction of the losses of active power in the lines, an improvement in the power factor and angular behavior; that complies with the restrictions set forth at a minimum operating cost. To model the problem, the IEEE 9-bar system was used.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectANÁLISIS DE SISTEMASspa
dc.subjectCAPACITANCIAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectGENERACIÓN DE ENERGÍA ELÉCTRICA DISTRIBUIDAspa
dc.subjectREDES ELÉCTRICASspa
dc.titleCompensación VOLT-VAR mediante despacho óptimo de generación en microrredes eléctricas con alta penetración de generación distribuidaspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - TTS159.pdfTexto completo1,08 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons