Análisis numérico de un sistema de calentamiento de agua utilizando un colector solar de placa plana

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18849
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorQuitiaquez, William-
dc.contributor.authorEstupiñán-Campos, José-
dc.contributor.authorIsaza-Roldán, C. A.-
dc.contributor.authorToapanta-Ramos, Fernando-
dc.contributor.authorLobato-Campoverde, Andrés-
dc.date.accessioned2020-07-28T01:54:35Z-
dc.date.available2020-07-28T01:54:35Z-
dc.date.issued2020-07-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18849-
dc.description.abstractEl objetivo de la presente investigación fue realizar un análisis numérico mediante CFD de un colector solar de placa plana; además, se realizó una comparación con resultados experimentales. El fluido de trabajo alcanzó una temperatura máxima de salida de 20.16 °C a las 12:00, el valor de la radiación solar se determinó para las coordenadas geográficas latitud -0.2252 y longitud -77.84; de forma similar, en este horario fue posible obtener una temperatura de la superficie del colector de 27.12 °C, como valor pico. Se determinó el menor rendimiento del dispositivo de transferencia de calor a las 10:00 con un valor de temperatura de salida del agua y temperatura máxima en la superficie del colector de 18.65 y 20.48 °C, respectivamente. Los resultados experimentales mostraron una temperatura máxima de 20.93 °C y una temperatura mínima de 19.4 °C, derivando en un error de 4.01 % entre la simulación computacional y los datos experimentales.//The aim of the present investigation was to perform a flat plate solar collector numerical analysis by CFD, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00, the value of solar radiation was determined for the geographical coordinates latitude -0.2252 and longitude -77.84, similarly, at this time it was possible to obtain a collector surface temperature of 27.12 °C, as a peak value. The heat transfer device lowest performance was determined at 10:00 with an outlet water temperature value and maximum temperature at the collector surface of 18.65 and 20.48 °C, respectively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectcolector; Collectorspa
dc.subjectenergía solar; solar energyspa
dc.subjecttemperatura; temperaturespa
dc.subjectsimulación CFD; CFD simulationspa
dc.titleAnálisis numérico de un sistema de calentamiento de agua utilizando un colector solar de placa planaspa
dc.typeArticlespa
Pertenece a las colecciones: Núm. 24 (julio-diciembre 2020)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ings_v24_Quitiaquez_Estupiñán_Isaza_Toapanta_Lobato.pdf2,57 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons