Ubicación de un sistema de compensación reactiva en la red de transmisión de energía eléctrica basado en programación no lineal entera mixta considerando cargabilidad de la red

Para citar o enlazar este item, por favor use el siguiente identificador: http://dspace.ups.edu.ec/handle/123456789/18408
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMuñoz Pilco, Jorge Paúl-
dc.contributor.authorGuzmán Rodríguez, Gonzalo Fabricio-
dc.date.accessioned2020-02-18T17:27:11Z-
dc.date.available2020-02-18T17:27:11Z-
dc.date.issued2020-02-
dc.identifier.urihttps://dspace.ups.edu.ec/handle/123456789/18408-
dc.descriptionLa presente investigación desarrolla un modelo de optimización para la óptima ubicación del dispositivo de compensación reactiva denominado STATCOM en sistemas de potencia, el modelo optimizador desarrollado se basa en programación no lineal entera mixta o MINLP y tiene como objetivo la reducción de pérdidas de potencia reactiva con lo que consecuentemente se reduce la cargabilidad de las líneas al generar un mejor balance de potencia reactiva en cada barra del sistema eliminando en parte la necesidad de que esta potencia sea cubierta por las unidades de generación disponibles en el sistema. Como efecto positivo también se mejora los perfiles de tensión en el sistema mejorando por tanto también un parámetro de calidad de servicio. El modelo ha sido ensayado en sistemas tipo IEEE de 9 y 39 barras y como límite se han ajustado 1, 2 y 3 dispositivos para el sistema de 9 barras mientras que para el sistema de 39 barras se ha permitido la máxima inserción de 1, 2 y 5 dispositivos en el sistema.spa
dc.description.abstractThe present investigation develops an optimization model for the optimal location of the reactive compensation device called STATCOM in power systems, the optimizer model developed is based on mixed integer nonlinear programming or MINLP and aims to reduce reactive power losses with which consequently reduces the chargeability of the lines by generating a better balance of reactive power in each bar of the system, partly eliminating the need for this power to be covered by the generation units available in the system. As a positive effect, the voltage profiles in the system are also improved, thus also improving a service quality parameter. The model has been tested in IEEE 9 and 39 bar type systems and as a limit 1, 2 and 3 devices have been set for the 9 bar system while for the 39 bar system the maximum insertion of 1, 2 has been allowed and 5 devices in the system.spa
dc.language.isospaspa
dc.rightsopenAccessspa
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Ecuador*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ec/*
dc.subjectINGENIERÍA ELÉCTRICAspa
dc.subjectOPTIMIZACIÓN MATEMÁTICAspa
dc.subjectREDES ELÉCTRICASspa
dc.subjectALMACENAMIENTO DE ENERGÍAspa
dc.subjectTRANSMISIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectDISTRIBUCIÓN DE ENERGÍA ELÉCTRICAspa
dc.subjectLÍNEAS ELÉCTRICASspa
dc.titleUbicación de un sistema de compensación reactiva en la red de transmisión de energía eléctrica basado en programación no lineal entera mixta considerando cargabilidad de la redspa
dc.typebachelorThesisspa
ups.carreraIngeniería Eléctricaspa
ups.sedeSede Quitospa
Pertenece a las colecciones: Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
UPS - ST004437.pdfTexto completo1,66 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons